Re: [Wien] GaP NMR chemical shift question

2014-04-21 Thread Robert Laskowski
Hi,

the metal option works only with TEMP Fermi method in in2. Maybe you have 
TETRA, in this case Fermi level is shifted by 0.5 Ry, leading to wrong 
shielding.

regards

Robert



On 18 April 2014 AM 11:07:27 Jing-Han Chen wrote:
 Dear WIEN2k users

   We tried to use NMR package to verify GaP chemical shift. It has
 been known to be a semiconductor and is fcc with one Ga at (0,0,0)and
 one P at (1/4,1/4,1/4). We tried to use default and metal option to
 obtain Sigma-ISO and it gave us a surprising difference as the
 following(11 k points)

 == default option ==

 :NMRTOT001  ATOM:   Ga   1  NMR(total/ppm) Sigma-ISO =   1353.09
   Sigma_xx =   1353.09   Sigma_yy =   1353.09   Sigma_zz =   1353.09
 :NMRASY001  ATOM:   Ga   1  NMR(total/ppm) ANISO (delta-sigma) =
0.00 ASYM (eta) = 0.000 SPAN =  0.00 SKEW = 1.000

 :NMRTOT002  ATOM:P   2  NMR(total/ppm) Sigma-ISO =377.85
   Sigma_xx =377.85   Sigma_yy =377.85   Sigma_zz =377.85
 :NMRASY002  ATOM:P   2  NMR(total/ppm) ANISO (delta-sigma) =
0.00 ASYM (eta) = 0.000 SPAN =  0.00 SKEW = 1.000

 == metal option ==

 :NMRTOT001  ATOM:   Ga   1  NMR(total/ppm) Sigma-ISO =   2704.12
   Sigma_xx =   2704.12   Sigma_yy =   2704.12   Sigma_zz =   2704.12
 :NMRASY001  ATOM:   Ga   1  NMR(total/ppm) ANISO (delta-sigma) =
0.00 ASYM (eta) = 0.000 SPAN =  0.00 SKEW = 1.000

 :NMRTOT002  ATOM:P   2  NMR(total/ppm) Sigma-ISO =   1082.72
   Sigma_xx =   1082.72   Sigma_yy =   1082.72   Sigma_zz =   1082.72
 :NMRASY002  ATOM:P   2  NMR(total/ppm) ANISO (delta-sigma) =
0.00 ASYM (eta) = 0.000 SPAN =  0.00 SKEW = 1.000

   The difference is more than 1000ppm for Ga atom. We do this test
 since we want to understand how metal option works and the proper
 usage/parameters.

   Any suggestion and comment are appreciated.


--
==
Dr. Robert Laskowski

Senior Scientist, Materials Science  Engineering Department
Institute of High Performance Computing, A*STAR
1 Fusionopolis Way, #16-16, Connexis, Singapore 138632
Tel(Off): +65. 64191493 Fax: +65. 64632536
=



This email is confidential and may be privileged. If you are not the intended 
recipient, please delete it and notify us immediately. Please do not copy or 
use it for any purpose, or disclose its contents to any other person. Thank you.
___
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html


[Wien] Output Coulomb potential

2014-04-21 Thread huimei liu
Dear staff:
The purpose of my calculations is to get quantity coulomb potential of
a certain system and I've already get the result.
But I'm confused with the component of coulomb potential, is the
contribution of core electron also counted  in or just the valence
electrons are calculated?
Thank you for your attention to this matter.
Best regards
Liu
___
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html


Re: [Wien] Output Coulomb potential

2014-04-21 Thread Gavin Abo
FYI, from slide 12 of 
http://indico.cern.ch/event/30902/session/19/contribution/95/material/slides/1.pdf 
:


The coulomb potential Vc is a central quantity in any theoretical 
calculation (part of the Hamiltonian) and is obtained from all charges 
rho (electronic + nuclear) in the system.


On 4/21/2014 8:11 AM, huimei liu wrote:

Dear staff:
The purpose of my calculations is to get quantity coulomb 
potential of a certain system and I've already get the result.
But I'm confused with the component of coulomb potential, is the 
contribution of core electron also counted  in or just the valence 
electrons are calculated?

Thank you for your attention to this matter.
Best regards
Liu
___
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html


Re: [Wien] Error in Parallel LAPW2

2014-04-21 Thread Gavin Abo

You should check for ghoststate:

http://www.mail-archive.com/wien%40zeus.theochem.tuwien.ac.at/msg08960.html

You can try adjusting RMT or energy parameters:

http://www.mail-archive.com/wien%40zeus.theochem.tuwien.ac.at/msg09842.html
http://www.wien2k.at/reg_user/faq/qtlb.html

If starting density is bad, sometimes adjust iqtlsave:

http://www.mail-archive.com/wien%40zeus.theochem.tuwien.ac.at/msg09836.html

On 4/20/2014 11:02 AM, Saleem Ayaz wrote:

Dear users
During SCF calculation of La2CrCoO6 I got the error
Error in LAPW2
 'LAPW2' - semicore band-ranges too large, ghostbands ?
**  testerror: Error in Parallel LAPW2

How to deal with this? Help me please.
___
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html


Re: [Wien] Output Coulomb potential

2014-04-21 Thread Peter Blaha

It is the coulomb potential due to ALL charges in your system.
This means the TOTAL electron density + nuclear charges.

Am 21.04.2014 16:11, schrieb huimei liu:

Dear staff:
 The purpose of my calculations is to get quantity coulomb potential
of a certain system and I've already get the result.
 But I'm confused with the component of coulomb potential, is the
contribution of core electron also counted  in or just the valence
electrons are calculated?
 Thank you for your attention to this matter.
Best regards
Liu


___
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html



--
Peter Blaha
Inst.Materials Chemistry
TU Vienna
Getreidemarkt 9
A-1060 Vienna
Austria
+43-1-5880115671
___
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html