Re: [Wien] opticcpara crashed for mstar

2021-03-04 Thread Rubel, Oleg
Oh, sorry about the misunderstanding. In your previous correspondence it 
sounded as you had a confusion about which klist file is used.

> In my case the CBM/CMB is at N-point which is located at 622 row number in 
> case.klist_band. But I have only 20 K-points in my case.klist and thus the 
> total KP in mstar output file is also 20.

To get band edges, I would check an eigenvalues file to identify band number 
XX, k point number YY, occupancy. Then look for a line "# KP: YY" and band XX 
below that in the output of mstar.

I hope it answers the question
Oleg
___
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html


Re: [Wien] opticcpara crashed for mstar

2021-03-04 Thread Dr. K. C. Bhamu
Dear Prof Oleg
I understand the procedure with case.klist or case.klist_band. my question
was not for the procedure.
My question is how to get m* from my attached files mstar output file? I
couldn't identify the KP index that has the m* for request VBM and cbm.
Please have a look on my supplied files.


Thank you very much
Bhamu

On Fri, Mar 5, 2021, 00:49 Rubel, Oleg  wrote:

> Dear Bhamu,
>
> mstar gets k points from case.mommat2[up/dn] file. It is create by OPTIC.
> The OPTIC, in turn, gets k points from vector files. Thus you need to have
> right k points in the vector files.
>
> The procedure described in
> https://github.com/rubel75/mstar/wiki/Tutorial-Si-with-SOC-(WIEN2k) has a
> part
>
> # WFs and eigenvalues with increased band range
> x lapw1
> x lapwso
>
> This will use case.klist (not case.klist_band) to generate vector files at
> LAPW1 step. Then it propagates to LAPWSO and OPTIC.
> If you want k points from case.klist_band, we need to generate vector
> files with (-band) option in LAPW1
>
> # WFs and eigenvalues with increased band range
> x lapw1 -band
> x lapwso
>
> There are not other changes in the workflow. Then k points from
> case.klist_band propagate into LAPWSO, OPTIC, and mstar eventually.
>
> Best regards
> Oleg
> ___
> Wien mailing list
> Wien@zeus.theochem.tuwien.ac.at
> http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
> SEARCH the MAILING-LIST at:
> http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html
>
___
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html


Re: [Wien] opticcpara crashed for mstar

2021-03-04 Thread Rubel, Oleg
Dear Bhamu,

mstar gets k points from case.mommat2[up/dn] file. It is create by OPTIC. The 
OPTIC, in turn, gets k points from vector files. Thus you need to have right k 
points in the vector files.

The procedure described in 
https://github.com/rubel75/mstar/wiki/Tutorial-Si-with-SOC-(WIEN2k) has a part

# WFs and eigenvalues with increased band range
x lapw1
x lapwso

This will use case.klist (not case.klist_band) to generate vector files at 
LAPW1 step. Then it propagates to LAPWSO and OPTIC.
If you want k points from case.klist_band, we need to generate vector files 
with (-band) option in LAPW1

# WFs and eigenvalues with increased band range
x lapw1 -band
x lapwso

There are not other changes in the workflow. Then k points from case.klist_band 
propagate into LAPWSO, OPTIC, and mstar eventually.

Best regards
Oleg
___
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html


Re: [Wien] opticcpara crashed for mstar

2021-03-04 Thread Dr. K. C. Bhamu
Dear Prof. Oleg,

I could not understand how to find the mstar for CBM and VBM.
I came across [1], where you are talking about case.klist_band. I
understand that the position of "G" Point is at 13 in that case so we need
to consider KP-13. Then the entry under KP-13 covers the band index. We can
get the band index from the case.bands.agr file.
Please correct me if I am wrong.

In my case the CBM/CMB is at N-point which is located at 622 row number in
case.klist_band. But I have only 20 K-points in my case.klist and thus the
total KP in mstar output file is also 20.
In my case.bands.agr the VBM  band index is 75. So what I understand is I
should find the 75th band index in mstar output file under KP-X (but here X
is unknown for me as case.klist file has only 20 k-points).
I am keeping my all necessary files here [2].

NOTE: I did not use case.klist_band file for the calculation and I am
keeping case.klist_band and case.bands.agr files [2] from my previously
finished calculation for band structure.

[1].
https://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/msg20713.html

[2]. https://we.tl/t-FsnY88gTgx

Thank you
Bhamu


On Thu, Mar 4, 2021 at 3:01 AM Rubel, Oleg  wrote:

> You are right, it is not a universal line. It implies that the system is
> not magnetic (N at the end). Also, it avoids relativistic local orbitals
> (RLOs), which is default in init_so_lapw. I cannot point to a reference,
> but it seems that optic is not compatible with RLOs? (Maybe someone can
> comment.)
>
> Thank you
> Oleg
> ___
> Wien mailing list
> Wien@zeus.theochem.tuwien.ac.at
> http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
> SEARCH the MAILING-LIST at:
> http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html
>
___
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html