[Wien] Problems of Error of charge leakage when calculating the effective U

2023-02-05 Thread via Wien
Dear WIEN2k experts and users,

I am a beginner of WIEN2k. The version is WIEN2k_21.1. Now, I am learning to 
calculate the effective U of Fe in Fe3Al, following the note ??Calculating the 
effective U in APW methods. NiO?? by Georg K.H. Madsen and Pavel Novak. When 
runsp the constrained calculation, the following messages and error appeared:

LAPW0 END

LAPW1 END

LAPW1 END

LAPW2 END

LAPW2 END

CORE END

CORE END

ERROR: NEC01 charge leakage too large
Could you please help me to check which part of my modification went wrong. 
Thank you for your reply in advance.
The specific procedures and related files are as follows:

1. The supercell of Fe3Al has been modified the first Fe. Then run x sgroup and 
copy case.struct_sgroup to case.struct. 

2. Modify inst so that the part of the first Fe looks like:

 Fe

Ar 3

3, 2,2.0 P

3, 2,2.0 P

3,-3,2.5 P

3,-3,0.0 P

4,-1,1.0 N

4,-1,0.5 N

Then run the following commands:

 x lstart

 x dstart

 x dstart ?Cup

 x dstart ?Cdn

runsp 

It's working fine up here.

3. Set two calculations. One with 3.5 (up), 3 (dn). The other with 3.5 (up), 2 
(dn). Make the bellowing 4 .inc files. And modified case.in1 and case.in2.

case.incup_+.50:

 7 1.00 0 NUMBER OF ORBITALS (EXCLUDING SPIN), SHIFT, IPRINT

1,-1,2
 ( N,KAPPA,OCCUP)

2,-1,2
 ( N,KAPPA,OCCUP)

2, 
1,2
 ( N,KAPPA,OCCUP)

2,-2,4
 ( N,KAPPA,OCCUP)

3,-1,2
 ( N,KAPPA,OCCUP)

3, 
2,4
 ( N,KAPPA,OCCUP)

3,-3,3
 ( N,KAPPA,OCCUP)



case.incdn_+.50:

7 1.00 0 NUMBER OF ORBITALS (EXCLUDING SPIN), SHIFT, IPRINT

(The first 5 lines are the same as the file above)

3, 
2,4
 ( N,KAPPA,OCCUP)

3,-3,2
 ( N,KAPPA,OCCUP)



case.incup_+.5-1:

7 1.00 0 NUMBER OF ORBITALS (EXCLUDING SPIN), SHIFT, IPRINT

(The first 5 lines are the same as the file above)

3, 
2,4
 ( N,KAPPA,OCCUP)

3,-3,3
 ( N,KAPPA,OCCUP)



case.incdn_+.5-1:

6 1.00 0 NUMBER OF ORBITALS (EXCLUDING SPIN), SHIFT, IPRINT

(The first 5 lines are the same as the file above)

3, 
2,4
 ( N,KAPPA,OCCUP)



Corresponding part of case.in1:

 0.30 4 0 (GLOBAL 
E-PARAMETER WITH n OTHER CHOICES, global APW/LAPW)

1 0.30 0. CONT 1

1 -3.97 0.0001 STOP 1

2 20.30 0.0010 CONT 1

0 0.30 0. CONT 1



The Original Fe3Al supercell had 408 valence electrons. I put 6.5 and 5.5 
electrons into the core.

Corresponding part of case.in2_+.50:

TOT 
(TOT,FOR,QTL,EFG,FERMI)

 -12.0 401.5 0.50 0.05 1 
EMIN, NE, ESEPERMIN, ESEPER0, iqtlsave



Corresponding part of case.in2_+.5-1:

TOT 
(TOT,FOR,QTL,EFG,FERMI)

 -12.0 402.5 0.50 0.05 1 
EMIN, NE, ESEPERMIN, ESEPER0, iqtlsave



Then Run the one constrained calulations.

cp case.in2_+.50 case.in2

cp case.incup_+.50 case.incup

cp case.incdn_+.50 case.incdn

runsp

Then the following messages and error appeared here:

LAPW0 END

LAPW1 END

LAPW1 END

LAPW2 END

LAPW2 END

CORE END

CORE END

ERROR: NEC01 charge leakage too large

Run the other constrained calulations.

cp case.in2_+.5-1 case.in2

cp case.incup_+.5-1 case.incup

cp case.incdn_+.5-1 case.incdn

runsp
For the _+.5-1, the same thing happens.I am looking forward your reply. 
Thank you in advance.
Best regards,

 

Yu___
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html


[Wien] Problems of calculating the effective U and setting shift during the supercell procedure

2022-11-14 Thread via Wien
Dear WIEN2k experts and users,
 
I am a beginner of WIEN2k. The version is WIEN2k_21.1. Now, I am learning to 
calculate the effective U following the note ??Calculating the effective U in 
APW methods. NiO?? by Georg K.H. Madsen and Pavel Novak. I have two problems 
about this topic. 
 
One is about generating a supercell. I generated the NiO.struct as the 
following: first get the NiO.cif from the external database, then by cif2struct 
to generate NiO.struct. During the supercell procedure, I set the numbers of 
xyz direction are all 2, but I am not sure how to set the optional shift (I 
think in this case I should set the optional shift are all 0?).
 
The other problem is if a supercell is required when we calculate the effective 
U. I am considering the material of Fe3Al, in which exist 12 Fe atoms. In this 
case, do I have to generate a supercell of Fe3Al to calculate the effective U 
of Fe? Or could I set one of Fe atoms as an impurity.
 Thank you for your reply in advance. 
Best regards,
 Yu___