Re: [Wien] NbNiO3 antiferromagnetic

2024-02-03 Thread delamora
Thank you Dr. Blaha
It worked fine.

Pablo

De: Wien  en nombre de Peter Blaha 

Enviado: sábado, 3 de febrero de 2024 02:47 a. m.
Para: wien@zeus.theochem.tuwien.ac.at 
Asunto: Re: [Wien] NbNiO3 antiferromagnetic

Hi,

I can confirm the problem. It is funny that this has never been reported
before.

The reason for the crash is that the program   orb  requires the atoms
sorted in ascending order. The init_orb script gives:

  1 4 0nmod, natorb, ipt
PRATT   1.0
1  1 3  index of atom, number of l, l
8  1 3  index of atom, number of l, l
2  1 2  index of atom, number of l, l
3  1 2  index of atom, number of l, l
...

but in order to work properly it should be

  1 4 0nmod, natorb, ipt
PRATT   1.0
1  1 3  index of atom, number of l, l
2  1 2  index of atom, number of l, l
3  1 2  index of atom, number of l, l
8  1 3  index of atom, number of l, l
...

Edit case.indm and inorb and sort the atoms properly (don't forget also
to sort the U values).

PS: rm *.dmat* *.vorb*

Regards




Am 03.02.2024 um 03:31 schrieb delamora:
> Dear WIEN2k users;
> I am calculating NdNiO3
> I did a ferromagnetic calculation without any problems.
> I wanted to calculate the antiferromagnetic case, so I splited the 4 Nd
> positions into 2 up and 2 dn, and when I ran the system, I had a problem;
> In the second cycle, when the 'orb -up' was executed, the system
> stopped, and I found that NdNiO3.vorbup contained only 1 line, when it
> should have many lines.
> Any suggestion?
>
> Pablo
>
> ___
> Wien mailing list
> Wien@zeus.theochem.tuwien.ac.at
> http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
> SEARCH the MAILING-LIST at:  
> http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html

--
--
Peter BLAHA, Inst.f. Materials Chemistry, TU Vienna, A-1060 Vienna
Phone: +43-1-58801-165300
Email: peter.bl...@tuwien.ac.atWIEN2k: http://www.wien2k.at
WWW:   http://www.imc.tuwien.ac.at
-
___
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html
___
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html


Re: [Wien] NbNiO3 antiferromagnetic

2024-02-03 Thread Peter Blaha

Hi,

I can confirm the problem. It is funny that this has never been reported 
before.


The reason for the crash is that the program   orb  requires the atoms 
sorted in ascending order. The init_orb script gives:


 1 4 0nmod, natorb, ipt
PRATT   1.0
1  1 3  index of atom, number of l, l
8  1 3  index of atom, number of l, l
2  1 2  index of atom, number of l, l
3  1 2  index of atom, number of l, l
...

but in order to work properly it should be

 1 4 0nmod, natorb, ipt
PRATT   1.0
1  1 3  index of atom, number of l, l
2  1 2  index of atom, number of l, l
3  1 2  index of atom, number of l, l
8  1 3  index of atom, number of l, l
...

Edit case.indm and inorb and sort the atoms properly (don't forget also 
to sort the U values).


PS: rm *.dmat* *.vorb*

Regards




Am 03.02.2024 um 03:31 schrieb delamora:

Dear WIEN2k users;
I am calculating NdNiO3
I did a ferromagnetic calculation without any problems.
I wanted to calculate the antiferromagnetic case, so I splited the 4 Nd 
positions into 2 up and 2 dn, and when I ran the system, I had a problem;
In the second cycle, when the 'orb -up' was executed, the system 
stopped, and I found that NdNiO3.vorbup contained only 1 line, when it 
should have many lines.

Any suggestion?

Pablo

___
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html


--
--
Peter BLAHA, Inst.f. Materials Chemistry, TU Vienna, A-1060 Vienna
Phone: +43-1-58801-165300
Email: peter.bl...@tuwien.ac.atWIEN2k: http://www.wien2k.at
WWW:   http://www.imc.tuwien.ac.at
-
___
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html


[Wien] NbNiO3 antiferromagnetic

2024-02-02 Thread delamora
Dear WIEN2k users;
I am calculating NdNiO3
I did a ferromagnetic calculation without any problems.
I wanted to calculate the antiferromagnetic case, so I splited the 4 Nd 
positions into 2 up and 2 dn, and when I ran the system, I had a problem;
In the second cycle, when the 'orb -up' was executed, the system stopped, and I 
found that NdNiO3.vorbup contained only 1 line, when it should have many lines.
Any suggestion?

Pablo


NdNiO3.struct
Description: NdNiO3.struct


NdNiO3.inorb
Description: NdNiO3.inorb


NdNiO3.vorbup
Description: NdNiO3.vorbup
___
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien