[Wien] c/a optimization

2015-06-15 Thread Seyyed Amir Abbas Emami
​dear wien2k users

I want to run c/a optimization (constant volume) on a compound which its origin 
structure is cubic now i have some questions:
 
 1- I know its cubic spacegroup but for c/a optimization in StructGen, i must 
create its tetragonal structure  or cubic space group is correct and just 
changing the c parameter arbitrary? And is there any further consideration?

2- 3% Rmt reduction is enough?
3- Is there any paper to help me in details about this problem. 


excuse me if i ask a simple question.I am a new man. I read some papers but i 
was not sure about this.

Thank you in advance___
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html


Re: [Wien] c/a optimization

2015-06-15 Thread delamora
You have to change the symmetry to tetragonal, change the c parameter by 0.001 
and the program will recognize that it is not cubic.


De: wien-boun...@zeus.theochem.tuwien.ac.at 
wien-boun...@zeus.theochem.tuwien.ac.at en nombre de Seyyed Amir Abbas Emami 
a.a.em...@birjand.ac.ir
Enviado: lunes, 15 de junio de 2015 12:14 p. m.
Para: wien@zeus.theochem.tuwien.ac.at
Asunto: [Wien] c/a optimization

?dear wien2k users

I want to run c/a optimization (constant volume) on a compound which its origin 
structure is cubic now i have some questions:

 1- I know its cubic spacegroup but for c/a optimization in StructGen, i must 
create its tetragonal structure  or cubic space group is correct and just 
changing the c parameter arbitrary? And is there any further consideration?

2- 3% Rmt reduction is enough?
3- Is there any paper to help me in details about this problem.


excuse me if i ask a simple question.I am a new man. I read some papers but i 
was not sure about this.

Thank you in advance
___
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html


[Wien] c/a optimization error

2011-01-26 Thread pu...@iitk.ac.in
Dear Prof Blaha and wien2k user
I am doing volume optimization for a tetragonal structure. First I have
done volume optimization along with force minimization.Then I am doing c/a
optimization for each volume(-4,-2,0,+2,+4).While doing c/a optimization
along with force minimization for -4%, -2% and 0% c/a structure,it is
working fine but for +2%  c/a structure it is giving this kind of error
and program is stopped.This happened two times.


   lapw0 -p(11:13:06) starting parallel lapw0 at Wed Jan 26 11:13:06
IST 2011
 .machine0 : processors
running lapw0 in single mode
**  lapw0 crashed!
5.880u 0.093s 0:06.08 98.1% 0+0k 0+0io 17pf+0w
error: command   /home1/puday/WIEN2K90/lapw0para lapw0.def   failed

   stop error


If I see the error in min.error file then it is showing

STOP in MINI, FORCES small

What should I do now?
Any help will be highly appreciated.


Regards,
Uday Bhanu Paramanik
Dept.of Physics
IIT Kanpur
India


[Wien] c/a optimization

2010-07-10 Thread shamik chakrabarti
Dear Peter Blaha Sir,

   should we change the indices in case.in0 to 0
0 0 and run the *c/a optimization again? *or after changing the indices what
command we should give?

Sir what is the meaning of *ifft parameters?*
*
*
*Sir actually we are giving an input structure having a c/a ratio 1.25

and expecting to get a ratio of 3.75. This thing we are doing because we are
giving an known structure as input and want to find the structure of a new
material. This material is formed due to the replacement of one atom in
A2BCO4 structure (c atom) by another atom say D and there is a material
ABDO4 having c/a ratio 3.75...although it is quite possible that ABDO4
and A2BDO4 have different c/a ratioour aim is only to obtained stable
c/a ratio for A2BDO4 structure.
*

*

*with best regards,

On Sat, Jul 10, 2010 at 4:27 PM, Peter Blaha
pblaha at theochem.tuwien.ac.atwrote:

 Change the indices in case.in0  to eg. 0  0  0   (this will recalculate
 the required ifft parameters).

 However: Please THINK what you are doing ???
 What is the meaning of changing c/a by factors of 3,4,5  ???
 Usually you change c/a by a few percent; i.e. 3% but not 300% !!!


  I was doing c/a optimization for an
  A2BCO4 type compound. The optimize.job file was created for structures
  having c/a 100%, 200%, 300% and 400% increased value than the input c/a..
  The program  calculates structures having c/a 100% and 200% more than
 input
  c/a but stopped after that by showing the following error:
 
  'SETFF1' - ifft too small in xcpot3
   'SETFF1' - 2*(KKK+1) LARGER THAN IFFT PARAMETERS IN
  XCPOT3
   'SETFF1' - KKK=   0   0
  45
   'SETFF1' - IIx=   0   0
  45
   'SETFF1' - IFFT= 108  96
  90
 
  I was chosen c/a value for more than 300% , 400%  than the input c/a.
 This
  was done as I beliveed  that the compound should  have much larger c/a
 ratio
 
  My question is what is the meaning of this error and how to remove it.
 Any
  response will be greatly appreciated. Thanks in advance.
 
  with regards,
  --
  Shamik Chakrabarti
  Research Scholar
  Dept. of Physics  Meteorology
  Material Processing  Solid State Ionics Lab
  IIT Kharagpur
  Kharagpur 721302
  INDIA
 


   P.Blaha
 --
 Peter BLAHA, Inst.f. Materials Chemistry, TU Vienna, A-1060 Vienna
 Phone: +43-1-58801-15671 FAX: +43-1-58801-15698
 Email: blaha at theochem.tuwien.ac.atWWW:
 http://info.tuwien.ac.at/theochem/
 --
 ___
 Wien mailing list
 Wien at zeus.theochem.tuwien.ac.at
 http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien




-- 
Shamik Chakrabarti
Research Scholar
Dept. of Physics  Meteorology
Material Processing  Solid State Ionics Lab
IIT Kharagpur
Kharagpur 721302
INDIA
-- next part --
An HTML attachment was scrubbed...
URL: 
http://zeus.theochem.tuwien.ac.at/pipermail/wien/attachments/20100710/b0ffc9a9/attachment.htm