Dear Wien2k users
I am little bit confused with the definition of the calculated optical property 
components. For instant, Im_epsilon_xx; what is the correct definition of this?
Is this the "IM_epsilon along x-direction when the external electric field is 
parallel to x-direction?" 
Further, if I have added spin orbital coupling along [010] direction, does that 
definition to the Im_epsilon_xx change?
I have another question regarding the SCISSOR_OPERATOR. When I think, this is 
used to match the band gaps when we have a smaller theoretical value than the 
experimental one. If anyone have some idea, please let me know whether it is a 
must for any semiconductor (metal oxide)?
For my case my calculated band gap is greater than the experimental one. Is 
there a way to get this matched to the experimental one ?
I am very much grateful for your help on the success of my project.
Thank you in advanceChami