Re: [WiX-users] Wix-3.0 and MDAC27ENU merge module

2007-10-17 Thread Mayur Oberoi

Did you ever find a solution? I am seeing the same warning. My initial guess
is that its happening because my merge modules are in Wix 1.0 and since then
they must have added more rules to the ICE validation

Thanks,
-M


David Howell-2 wrote:
 
 Hi Again,
 
 I am now trying to using the MDAC27ENU.MSM in my wix-3.0 project.
 
 Again, this msm was obtained from the InstallShield (or MS) website.
 
 When I run light, I receive the following warnings and errors:
 
 Microsoft (R) Windows Installer Xml Linker version 3.0.2015.0
 Copyright (C) Microsoft Corporation 2003. All rights reserved.
 
 .wxs(28) : warning LGHT1056 : The Directory table contains a row with 
 primary key(s) 'DesktopFolder' which cannot be merged from the merge 
 module 'C:\Merge Modules\mdac27enu.MSM'.  This is likely due to 
 collision of rows with the same primary key(s) (but other different 
 values in other columns) between the database and the merge module.
 
 .wxs(28) : warning LGHT1056 : The Directory table contains a row with 
 primary key(s) 'ProgramFilesFolder' which cannot be merged from the 
 merge module 'C:\Merge Modules\mdac27enu.MSM'.  This is likely due to 
 collision of rows with the same primary key(s) (but other different 
 values in other columns) between the database and the merge module.
 
 .wxs(28) : warning LGHT1056 : The Directory table contains a row with 
 primary key(s) 'SystemFolder' which cannot be merged from the merge 
 module 'C:\Merge Modules\mdac27enu.MSM'.  This is likely due to 
 collision of rows with the same primary key(s) (but other different 
 values in other columns) between the database and the merge module.
 
 light.exe : error LGHT0204 : ICE99: The directory name: 
 PrimaryVolumePath is the same as one of the MSI Public Properties and 
 can cause unforeseen side effects.
 
 light.exe : error LGHT0204 : ICE99: The directory name: WindowsVolume is 
 the same as one of the MSI Public Properties and can cause unforeseen 
 side effects.
 
 If I don't include this particular merge module, I don't receive any 
 warnings or errors.
 
 I understand I can ignore the warnings, however how do I overcome the 
 errors?
 
 Cheers,
 
 David.
 
 -
 Using Tomcat but need to do more? Need to support web services, security?
 Get stuff done quickly with pre-integrated technology to make your job
 easier
 Download IBM WebSphere Application Server v.1.0.1 based on Apache Geronimo
 http://sel.as-us.falkag.net/sel?cmd=lnkkid=120709bid=263057dat=121642
 ___
 WiX-users mailing list
 WiX-users@lists.sourceforge.net
 https://lists.sourceforge.net/lists/listinfo/wix-users
 
 

-- 
View this message in context: 
http://www.nabble.com/Wix-3.0-and-MDAC27ENU-merge-module-tf2156640.html#a13262200
Sent from the wix-users mailing list archive at Nabble.com.


-
This SF.net email is sponsored by: Splunk Inc.
Still grepping through log files to find problems?  Stop.
Now Search log events and configuration files using AJAX and a browser.
Download your FREE copy of Splunk now  http://get.splunk.com/
___
WiX-users mailing list
WiX-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/wix-users


[WiX-users] Wix-3.0 and MDAC27ENU merge module

2006-08-23 Thread David Howell
Hi Again,

I am now trying to using the MDAC27ENU.MSM in my wix-3.0 project.

Again, this msm was obtained from the InstallShield (or MS) website.

When I run light, I receive the following warnings and errors:

Microsoft (R) Windows Installer Xml Linker version 3.0.2015.0
Copyright (C) Microsoft Corporation 2003. All rights reserved.

.wxs(28) : warning LGHT1056 : The Directory table contains a row with 
primary key(s) 'DesktopFolder' which cannot be merged from the merge 
module 'C:\Merge Modules\mdac27enu.MSM'.  This is likely due to 
collision of rows with the same primary key(s) (but other different 
values in other columns) between the database and the merge module.

.wxs(28) : warning LGHT1056 : The Directory table contains a row with 
primary key(s) 'ProgramFilesFolder' which cannot be merged from the 
merge module 'C:\Merge Modules\mdac27enu.MSM'.  This is likely due to 
collision of rows with the same primary key(s) (but other different 
values in other columns) between the database and the merge module.

.wxs(28) : warning LGHT1056 : The Directory table contains a row with 
primary key(s) 'SystemFolder' which cannot be merged from the merge 
module 'C:\Merge Modules\mdac27enu.MSM'.  This is likely due to 
collision of rows with the same primary key(s) (but other different 
values in other columns) between the database and the merge module.

light.exe : error LGHT0204 : ICE99: The directory name: 
PrimaryVolumePath is the same as one of the MSI Public Properties and 
can cause unforeseen side effects.

light.exe : error LGHT0204 : ICE99: The directory name: WindowsVolume is 
the same as one of the MSI Public Properties and can cause unforeseen 
side effects.

If I don't include this particular merge module, I don't receive any 
warnings or errors.

I understand I can ignore the warnings, however how do I overcome the 
errors?

Cheers,

David.

-
Using Tomcat but need to do more? Need to support web services, security?
Get stuff done quickly with pre-integrated technology to make your job easier
Download IBM WebSphere Application Server v.1.0.1 based on Apache Geronimo
http://sel.as-us.falkag.net/sel?cmd=lnkkid=120709bid=263057dat=121642
___
WiX-users mailing list
WiX-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/wix-users