I would imagine you need to re-tokenise (open the method and press
function+return or enter) the method
for the now-process-varaible token to connect to the newly created method.
or, perhaps you could use the global find-and-replace feature (which
re-tokenises what it replaced)
by replacing the
Koen,
Thank you for both postings. I was able to get into the design environment and
after a bit of a battle with the bad method I was able to delete it and flush
it from the trash.
Miyako,
I did not really understand your comment:
- rather than going to Design the normal way, you could
rather than going to Design the normal way,
you could open the DB directly with the MSC.
> 2017/02/08 0:50、Douglas Cryer のメール:
> I had a situation today where the database crashed when writing a method and
> now when I open the design environment the methods start
Hi Doug,
One more thing...
If one of your methods is damaged (causes 4D crash), the Explorer could also
crash when trying to display the method code preview.
Yet again the option key comes to rescue. If holding that key and selecting a
method, the Explorer will not redraw the preview pane.
Hi Doug,
Have you tried to hold the alt key when opening the database or when going to
design environment.
In standalone you will get the 'You pressed the "Option" key' dialog, just
click Continue, but keep pressing the alt key. The design environment should
not open any left open method
No longer data check and structure check are no more I know there was a beta of
an upgrade but as far as I know never completed
Regards
Chuck
Sent from my iPhone
> On Feb 7, 2017, at 10:50 AM, Douglas Cryer <jdcr...@telekinetix.com> wrote:
>
> Hi folks,
>
> Are there an
Hi folks,
Are there any 3rd party structure repair tools for 4D v15?
I had a situation today where the database crashed when writing a method and
now when I open the design environment the methods start opening and the
database crashes.
No way to open the design environment AT ALL. I have