Re: LTO drive replacement when using switch zoning

2009-08-28 Thread Gill, Geoffrey L.
: LTO drive replacement when using switch zoning Gill, I suspect that the ce had the drive in service mode, either to swap the drive for another one, or to run diag tests. The ce would have to take it out of service mode. This can be done from the front panel of the library. Or some cable

Re: LTO drive replacement when using switch zoning

2009-08-19 Thread Zoltan Forray/AC/VCU
drive replacement when using switch zoning Sent by: ADSM: Dist Stor Manager ADSM-L@VM.MARIST.EDU It is undocumented, but when replacing fibre-connected LTO drives you must halt and restart the TSM server in order for it to correctly sense the new serial numbers. Nothing will work on the new replaced

Re: LTO drive replacement when using switch zoning

2009-08-19 Thread Skylar Thompson
Roger Deschner wrote: It is undocumented, but when replacing fibre-connected LTO drives you must halt and restart the TSM server in order for it to correctly sense the new serial numbers. Nothing will work on the new replaced drive until you bounce the server. A Sun/STK engineer told me about

Re: LTO drive replacement when using switch zoning

2009-08-19 Thread Len Boyle
, 2009 9:42 AM To: ADSM-L@VM.MARIST.EDU Subject: Re: [ADSM-L] LTO drive replacement when using switch zoning If replacing the drive is truly a straight up swap-out, the the new drive will have a new wwn that will need to be zoned in the san switch. Then in AIX it will show up as a new rmt device

Re: LTO drive replacement when using switch zoning

2009-08-19 Thread Gill, Geoffrey L.
Of Richard Rhodes Sent: Wednesday, August 19, 2009 9:42 AM To: ADSM-L@VM.MARIST.EDU Subject: Re: [ADSM-L] LTO drive replacement when using switch zoning If replacing the drive is truly a straight up swap-out, the the new drive will have a new wwn that will need to be zoned in the san switch

Re: LTO drive replacement when using switch zoning

2009-08-19 Thread Len Boyle
-L@VM.MARIST.EDU Subject: Re: LTO drive replacement when using switch zoning If one is using the ibm 3584(aka TS3500) then the wwn does not changes on a straight up swap-out. The wwn goes with the slot in the library used to hold the tape drive and not the tape drive itself. And with lto-3

LTO drive replacement when using switch zoning

2009-08-18 Thread Gill, Geoffrey L.
Hi all, This situation has never happened to me before so I'm a little unsure of the steps and order to fix it. Running AIX 5.3 with a TSM instance at 5.5.1. LTO drives are zoned in through a switch to the TSM server, 2 drives to each fibre card. Support for the IBM drives was not renewed with

Re: LTO drive replacement when using switch zoning

2009-08-18 Thread Roger Deschner
It is undocumented, but when replacing fibre-connected LTO drives you must halt and restart the TSM server in order for it to correctly sense the new serial numbers. Nothing will work on the new replaced drive until you bounce the server. A Sun/STK engineer told me about this one. I know this is