Re: [AFMUG] Mikrotik Cloud Router Switch and 1Gbps
Ordered some SPF copper gigabit modules. Perhaps they will work better? On Wed, Jun 21, 2017 at 7:11 PM, Mattwrote: > Yes, I meant cat-5e. We typically use Apex9 shielded outdoor with ez > shielded connectors. > > > > On Wed, Jun 21, 2017 at 6:50 PM, Matt wrote: >> We use a lot of these Mikrotik 24 port rack mount switches. Does >> anyone else have trouble getting there copper ethernet ports to hold >> 1Gbps connections on around 150 foot cat-5 runs with APC surge >> arrestors? >> >> I have had this issue with PMP450i gear doing sync over power but now >> I am having the issue with SAF Lumina gear as well and there is no >> sync over power there.
Re: [AFMUG] Mikrotik Cloud Router Switch and 1Gbps
I have a water tower with ~165 of cat5 (not e) Superior Essex armored 25-pair with GigE links running just fine. On 6/21/2017 6:57 PM, Chris Wright wrote: Gigabit on Cat5 is only good for about 80 feet. Chris Wright Network Administrator -Original Message- From: Af [mailto:af-boun...@afmug.com] On Behalf Of Matt Sent: Wednesday, June 21, 2017 4:51 PM To: af@afmug.com Subject: [AFMUG] Mikrotik Cloud Router Switch and 1Gbps We use a lot of these Mikrotik 24 port rack mount switches. Does anyone else have trouble getting there copper ethernet ports to hold 1Gbps connections on around 150 foot cat-5 runs with APC surge arrestors? I have had this issue with PMP450i gear doing sync over power but now I am having the issue with SAF Lumina gear as well and there is no sync over power there.
Re: [AFMUG] Mikrotik Cloud Router Switch and 1Gbps
Yes, I meant cat-5e. We typically use Apex9 shielded outdoor with ez shielded connectors. On Wed, Jun 21, 2017 at 6:50 PM, Mattwrote: > We use a lot of these Mikrotik 24 port rack mount switches. Does > anyone else have trouble getting there copper ethernet ports to hold > 1Gbps connections on around 150 foot cat-5 runs with APC surge > arrestors? > > I have had this issue with PMP450i gear doing sync over power but now > I am having the issue with SAF Lumina gear as well and there is no > sync over power there.
Re: [AFMUG] Mikrotik Cloud Router Switch and 1Gbps
No way.. Cat5 maybe. Who uses that? I would assume he means cat5e. Which should have no trouble holding 1g link at 300+ feet. At a previous job a customer didn't want to put fiber in to a remote building so we pulled cat5e 550'. The only test that failed on the fluke dtx-1800 was length. On Jun 21, 2017 6:57 PM, "Chris Wright" <ch...@velociter.net> wrote: > Gigabit on Cat5 is only good for about 80 feet. > > Chris Wright > Network Administrator > > -Original Message- > From: Af [mailto:af-boun...@afmug.com] On Behalf Of Matt > Sent: Wednesday, June 21, 2017 4:51 PM > To: af@afmug.com > Subject: [AFMUG] Mikrotik Cloud Router Switch and 1Gbps > > We use a lot of these Mikrotik 24 port rack mount switches. Does anyone > else have trouble getting there copper ethernet ports to hold 1Gbps > connections on around 150 foot cat-5 runs with APC surge arrestors? > > I have had this issue with PMP450i gear doing sync over power but now I am > having the issue with SAF Lumina gear as well and there is no sync over > power there. > >
Re: [AFMUG] Mikrotik Cloud Router Switch and 1Gbps
Gigabit on Cat5 is only good for about 80 feet. Chris Wright Network Administrator -Original Message- From: Af [mailto:af-boun...@afmug.com] On Behalf Of Matt Sent: Wednesday, June 21, 2017 4:51 PM To: af@afmug.com Subject: [AFMUG] Mikrotik Cloud Router Switch and 1Gbps We use a lot of these Mikrotik 24 port rack mount switches. Does anyone else have trouble getting there copper ethernet ports to hold 1Gbps connections on around 150 foot cat-5 runs with APC surge arrestors? I have had this issue with PMP450i gear doing sync over power but now I am having the issue with SAF Lumina gear as well and there is no sync over power there.
[AFMUG] Mikrotik Cloud Router Switch and 1Gbps
We use a lot of these Mikrotik 24 port rack mount switches. Does anyone else have trouble getting there copper ethernet ports to hold 1Gbps connections on around 150 foot cat-5 runs with APC surge arrestors? I have had this issue with PMP450i gear doing sync over power but now I am having the issue with SAF Lumina gear as well and there is no sync over power there.