Re: how to use runtapes 1 with single lto drive setup

2013-07-09 Thread Karsten Fuhrmann
Hello, i updated to amanda 3.3.4 now, but the problem still persists. I got no email from amanda and amstatus after an amflush run shows the same as before. Any clues? Here is a my amanda.conf: # Global Settings

Re: how to use runtapes 1 with single lto drive setup

2013-07-09 Thread Jean-Louis Martineau
Interactivity do not work with the default traditional taperscan, you must use lexical or oldest. define taperscan mytaperscan { plugin lexical #plugin oldest } taperscan mytaperscan see: man amanda-taperscan Jean-Louis On 07/09/2013 07:28 AM, Karsten Fuhrmann wrote: Hello, i updated to

Re: how to use runtapes 1 with single lto drive setup

2013-07-05 Thread Karsten Fuhrmann
Hello, i tried that, but didnt work. I ran an amflush and after the first tape was filled up the amflush finished without sending the email to change the tape. It did not even sent the normal email that it finished the amdump. It just quietly terminated amdump. I am still using amanda 3.3.3 but

Re: how to use runtapes 1 with single lto drive setup

2013-07-03 Thread Jean-Louis Martineau
Karsten, see: man amanda-interactivity tpchanger chg-single:tape:/dev/nst0 define interactivity email { plugin email property mailto m...@me.me } interactivity email runtapes 2 Jean-Louis On 07/02/2013 11:04 AM, Karsten Fuhrmann wrote: Hello, i am trying to get this working for ages,

how to use runtapes 1 with single lto drive setup

2013-07-02 Thread Karsten Fuhrmann
Hello, i am trying to get this working for ages, but i seem to miss something all the time. So i just want to use runtapes 1 because some of my filesystems are bigger than my tapesize. I dont have a robot changer, just a lto drive, so i have to change tapes by hand. I would like to get an