Re: [asterisk-users] dahdi timing source multiple cards

2012-12-27 Thread Dave George
Thanks Matt. The suggestion helped. No more slip erros. Dave > Original Message > Subject: Re: [asterisk-users] dahdi timing source multiple cards > From: Matthew Fredrickson > Date: Fri, December 21, 2012 3:41 pm > To: asterisk-users@lists.digium.com >

Re: [asterisk-users] dahdi timing source multiple cards

2012-12-21 Thread Matthew Fredrickson
You must make sure that for each card, the timing parameter does not exceed the number of spans on the card (unless you're using a timing cable between cards). So you probably don't want to have anything above a 4 for the timing parameter... I see below that you have 5-12 listed in the timing

[asterisk-users] dahdi timing source multiple cards

2012-12-20 Thread Dave George
I have a box with 12 T1s (4 Te410P cards). The PSTN provider is reporting slips and ask me to update the clock source. I have my system.conf set as the following but when I run dahdi_scan only the ports on Card 1 are showing up with syncsrc=1 system.conf : span=1,1,0,esf,b8zs bchan=2-24 m