Re: Power save setting while interface is down

2023-11-21 Thread James Prestwood
Hi Kalle, On 11/21/23 06:15, Kalle Valo wrote: James Prestwood writes: Hi, I've noticed a somewhat rare behavior (<1% of the time) where bringing an interface up fails after disabling power save. This is done by IWD when a user-option is enabled, and follows an interface removal/creation.

Re: Power save setting while interface is down

2023-11-21 Thread Kalle Valo
James Prestwood writes: > Hi, > > I've noticed a somewhat rare behavior (<1% of the time) where bringing > an interface up fails after disabling power save. This is done by IWD > when a user-option is enabled, and follows an interface > removal/creation. The sequence is: > > 1. Remove default

Power save setting while interface is down

2023-11-20 Thread James Prestwood
Hi, I've noticed a somewhat rare behavior (<1% of the time) where bringing an interface up fails after disabling power save. This is done by IWD when a user-option is enabled, and follows an interface removal/creation. The sequence is: 1. Remove default interface 2. Create new interface