Re: [Bacula-users] Bacula fails with Blocked Drive.

2019-07-10 Thread Martin Simmons
The output below shows an autochanger problem when you ran btape fill: > 02-Jul 16:27 btape JobId 0: 3304 Issuing autochanger "load slot 1, drive > 1" command. > 02-Jul 16:32 btape JobId 0: Fatal error: 3992 Bad autochanger "load slot > 1, drive 1": ERR=Child died from signal 15: Termination. >

Re: [Bacula-users] [EXTERNAL] Bacula fails with Blocked Drive.

2019-07-10 Thread Clark, Patti via Bacula-users
Sometimes I’ve had a BLOCKED device it has been due to a race condition in Bacula between 2 jobs requesting different media for the same drive. Usually it can be corrected by canceling one of the jobs. Other times it is due to a “failed” job that is not cleaned up completely leaving a

Re: [Bacula-users] Safely reusing tapes that are still labelled as Full

2019-07-10 Thread Heitor Faria
> Hello Hello William, > I stated using bacula about 6 months ago. When I originally set it up, I just > specified Volume retention period. The File Retention period, and the Job > Retention period periods are longer and hence most of the tapes aren't still > labelled as ready for recycle. >

[Bacula-users] Bacula fails with Blocked Drive.

2019-07-10 Thread Jeffrey DiDomenico
Hi, I know you guys are volunteers but any help would be greatly appreciated. Please help me with the following problem. I have been working on this for some time but can't find a solution on the internet. I can understand if "Device is BLOCKED waiting for mount of volume" can mean several