Re: [Bacula-users] New autochanger adds L3 after tape barcode

2009-10-20 Thread Edward M. Markowski
Check the autochanger user doc, many have a setting that will cause it to stop reporting the cartrage type field. On Mon, 19 Oct 2009, Adam Cécile wrote: Hello, I juste replaced an autochanger and the new one adds L3 at the end of each tape label (ie: XY becames XYL3). What can I

[Bacula-users] New autochanger adds L3 after tape barcode

2009-10-19 Thread Adam Cécile
Hello, I juste replaced an autochanger and the new one adds L3 at the end of each tape label (ie: XY becames XYL3). What can I do to keep the same names as before ? Thanks in advance, Regards, Adam. -- Adam Cécile Mandriva / Linbox 152, rue de

Re: [Bacula-users] New autochanger adds L3 after tape barcode

2009-10-19 Thread Arno Lehmann
Hi, 19.10.2009 11:29, Adam Cécile wrote: Hello, I juste replaced an autochanger and the new one adds L3 at the end of each tape label (ie: XY becames XYL3). So it's using LTO-3 drives. It's a strong recommendation (actually an IBM standard) with LTO autochangers that they encode

Re: [Bacula-users] New autochanger adds L3 after tape barcode

2009-10-19 Thread Wolfgang Denk
Dear Adam, In message 4adc3194.20...@linbox.com you wrote: I juste replaced an autochanger and the new one adds L3 at the end of = each tape label (ie: XY becames XYL3). What can I do to keep the same names as before ? Why don't you filter the names in the mtx-changer script?

Re: [Bacula-users] New autochanger adds L3 after tape barcode

2009-10-19 Thread Adam Cécile
Wolfgang Denk a écrit : Dear Adam, In message 4adc3194.20...@linbox.com you wrote: I juste replaced an autochanger and the new one adds L3 at the end of = each tape label (ie: XY becames XYL3). What can I do to keep the same names as before ? Why don't you filter the