i can confirm this problem,
bacula loads the slot where the tape is last seen,
even if the inchanger flag ist set to 0.
(you can find more about my problem in Re: [Bacula-users] Restore Bug? on
20.10.2008.)
i think this is a bug.
Best Regards
Thomas
LeJav schrieb:
Hello,
I have removed a
A workaround I have found is to set the slot number to 0 (using update volumes);
thus, when restoring, bacula finds a bad slot number and asks immediately for
intervention:
28-Oct 07:59 fn-archnfs-sd JobId 274: Invalid slot=0 defined in catalog for
Volume NF0020L3 on Drive-1 (/dev/nst0).
Hello,
I have removed a tape from my autochanger, and I have set the InChanger flag to 0
with the update volume command
Now, I try to restore a file from this tape.
I would expect that bacula asks for an intervention to insert the missing tape;
instead,
bacula trie to mount the missing tape