On Nov 10, 2014, at 3:33 AM, Andrey Chebotarev a...@525.su wrote:
Hi.
It's in devel because the question about editing sources, but not about
configuration.
And I think solve the question could only developer.
The conclusion to change the code is premature.
On Nov 4, 2014, at
Mr. Andrey,
/etc/bacula/scripts/mtx-changer:
wait_for_drive() {
i=0
while [ $i -le 300 ]; do # Wait max 300 seconds
if mt -f $1 status 21 | grep ${ready} /dev/null 21; then
break
fi
debug Device $1 - not ready, retrying...
sleep 1
i=`expr $i + 1`
done
}
Regards,
Consider a admin job where the drive is cleaned. I'm very confused by the
library needing to clean so often.
--
Dan Langille
http://langille.org/
On Nov 10, 2014, at 7:45 AM, Andrey Chebotarev a...@525.su wrote:
Ok, may be there is another solution.
Let's put everything in one place:
I
On Nov 10, 2014, at 7:45 AM, Andrey Chebotarev a...@525.su wrote:
Ok, may be there is another solution.
Let's put everything in one place:
I have very long jobs, which spend 30-40 cartridges per one.
I have library which have to be configured with auto cleaning.
During running job after
There is no need to modify the code.
Just modify the bacula-sd.conf file. It is much easier.
Best regards,
Kern
On 11/10/2014 04:14 PM, Andrey Chebotarev wrote:
I've modified and recompiled, waiting
for result till
On Nov 10, 2014, at 11:22 AM, Kern Sibbald k...@sibbald.com wrote:
There is no need to modify the code. Just modify the bacula-sd.conf file.
It is much easier.
Best regards,
Kern
I think Kern refers to here:
On Nov 8, 2014, at 7:28 PM, Dan Langille d...@langille.org
mailto:d...@langille.org wrote:
On Nov 4, 2014, at 6:55 AM, Andrey Chebotarev a...@525.su
mailto:a...@525.su wrote:
Hi guys.
I use bacula 5.2.13 with IBM TS3200 library.
Periodically I face problem with load slot time
Hello,
Assuming you are using the Bacula mtx-changer script.
In case of really big problems with the mtx-changer script, the
first step is to execute it by hand and see what it outputs. The
second step is to set the environment variable debug_log=1
On 09/11/2014, at 17.14, Dan Langille d...@langille.org wrote:
Five minutes to load a tape is way too long for something which succeeds. My
hypothesis: there is a problem with the process.
Yes and no
If the tape has been closed properly then Yes, if it hasnt the first thing the
drive is
On 11/10/2014 06:54 AM, Jesper Krogh wrote:
On 09/11/2014, at 17.14, Dan Langille d...@langille.org wrote:
Five minutes to load a tape is way too long for something which succeeds.
My hypothesis: there is a problem with the process.
Yes and no
If the tape has been closed properly then
On Nov 4, 2014, at 6:55 AM, Andrey Chebotarev a...@525.su
mailto:a...@525.su wrote:
Hi guys.
I use bacula 5.2.13 with IBM TS3200 library.
Periodically I face problem with load slot time out. In logs it looks lilke:
22-Sep 00:35 baculasrv-dir JobId 10471: Recycled volume 220AAAL6
11 matches
Mail list logo