Re: [Bloat] We built a new bufferbloat test and keen for feedback

2020-11-04 Thread Y via Bloat
https://www.waveform.com/apps/dev-arshan?test-id=a9f994a0-171c-48d3-a40d-1550f13b2319 Great job. This is the result of my slow internees. I would like to know the criteria for the grade. Le jeudi 5 novembre 2020 à 08:54:57 UTC+9, Toke Høiland-Jørgensen via Bloat a écrit : Sam

Re: [Bloat] Router congestion, slow ping/ack times with kernel 5.4.60

2020-11-04 Thread Toke Høiland-Jørgensen via Bloat
"Thomas Rosenstein" writes: > On 4 Nov 2020, at 17:10, Toke Høiland-Jørgensen wrote: > >> Thomas Rosenstein via Bloat writes: >> >>> Hi all, >>> >>> I'm coming from the lartc mailing list, here's the original text: >>> >>> = >>> >>> I have multiple routers which connect to multiple upstream

Re: [Bloat] We built a new bufferbloat test and keen for feedback

2020-11-04 Thread Toke Høiland-Jørgensen via Bloat
Sam Westwood writes: > Hi everyone, > > My name is Sam and I'm the co-founder and COO of Waveform.com. At Waveform > we provide equipment to help improve cell phone service, and being in the > industry we've always been interested in all aspects of network > connectivity. Bufferbloat for us has

[Bloat] We built a new bufferbloat test and keen for feedback

2020-11-04 Thread Sam Westwood
Hi everyone, My name is Sam and I'm the co-founder and COO of Waveform.com. At Waveform we provide equipment to help improve cell phone service, and being in the industry we've always been interested in all aspects of network connectivity. Bufferbloat for us has always been interesting, and while

Re: [Bloat] Router congestion, slow ping/ack times with kernel 5.4.60

2020-11-04 Thread Thomas Rosenstein via Bloat
On 4 Nov 2020, at 17:10, Toke Høiland-Jørgensen wrote: Thomas Rosenstein via Bloat writes: Hi all, I'm coming from the lartc mailing list, here's the original text: = I have multiple routers which connect to multiple upstream providers, I have noticed a high latency shift in icmp

Re: [Bloat] Router congestion, slow ping/ack times with kernel 5.4.60

2020-11-04 Thread Toke Høiland-Jørgensen via Bloat
Thomas Rosenstein via Bloat writes: > Hi all, > > I'm coming from the lartc mailing list, here's the original text: > > = > > I have multiple routers which connect to multiple upstream providers, I > have noticed a high latency shift in icmp (and generally all connection) > if I run b2

[Bloat] Router congestion, slow ping/ack times with kernel 5.4.60

2020-11-04 Thread Thomas Rosenstein via Bloat
Hi all, I'm coming from the lartc mailing list, here's the original text: = I have multiple routers which connect to multiple upstream providers, I have noticed a high latency shift in icmp (and generally all connection) if I run b2 upload-file --threads 40 (and I can reproduce this)