Re: [casper] Casper 10.1 library issue

2008-10-29 Thread Wan.Cheng
HI Laura: Thanks for your help. You are right. If I set more samples per period, it is more difficult for me to find the difference. I setup the sine wave according your setting, the difference is obvious. I think you explanation for the ADC internal structure is correct. The extra delay in O1

Re: [casper] Casper 10.1 library issue

2008-10-29 Thread Laura Spitler
Hi Wan, That is strange. I made a model that looks identical to your AC_test using 10.1, and the output looks correct. Here are the parameters I'm using for the 'Sine Wave' block: Sine type : Sample based Amplitude: 1 Bias: 0 Samples per period: 10 Number of offset samples: 0 Sample time: 1/8 The