Hi David, you can also just unplug the USB, this forces the FTDI chip into
reset and then you can use chipscope.
Regards
Alec
On Thu, Nov 21, 2013 at 9:56 AM, Wesley New wes...@ska.ac.za wrote:
You can run this script
Does anyone have experience using chipScope with Platform Cable USB II on
roach2? I know it is not necessary given all the CASPER superstructure, but
does anything on the roach2 prevent it?
--
David P. Saroff
Rochester Institute of Technology
54 Lomb Memorial Dr, Rochester, NY 14623
Hi David yes the ftdi chip hogs the bus. Ill send you a script to release
the jtag when I get into the office.
Regards
Wes
On 20 Nov 2013 21:53, DAVID SAROFF (RIT Student) dps7...@rit.edu wrote:
Does anyone have experience using chipScope with Platform Cable USB II on
roach2? I know it is not
You can run this script
https://github.com/ska-sa/roach2_support_software/blob/master/ftdi/scripts/release_jtag_port.py
You will need python and the ftdi libraries.
Wesley New
South African SKA Project
+2721 506 7365
www.ska.ac.za
On Thu, Nov 21, 2013 at 7:49 AM, Wesley New wes...@ska.ac.za
4 matches
Mail list logo