Re: [casper] ROACH2 U-boot failure / USB failure

2017-06-13 Thread Tony Goodson
Thanks Alec, That worked! I'm used to always having a minicom terminal up at start. When I didn't, it successfully reloaded u-boot. We're up and running now. Really appreciate the help! --Tony Goodson R On Tue, Jun 13, 2017 at 12:47 AM, Alec Rust wrote: > Hi Tony, the

Re: [casper] ROACH2 U-boot failure / USB failure

2017-06-13 Thread Alec Rust
Hi Tony, the initial u-boot is transferred using x-modem. This is done via serial link. If you have a minicom session open there will be a com port clash. Try again with minicom closed. Regards Alec PS. I'll go take a look at the code and see what else could be wrong but I think it's just a com