Re: [OSL | CCIE_Voice] Gatekeeper config - solution for Single trunk, no BW CLI, no location, one call in sub and redundancy over PSTN

2009-04-18 Thread anil batra
Hi Prabahar,   On the call from CME, GK finds that the priority 10 trunk is already max out and tries the priority 9 trunk (pub) to make the call. I found that the call still goes thru H323-ID: CCM2CME_2 , even though there was one active call on H323-ID: CCM2CME_2 , the second call from CME

Re: [OSL | CCIE_Voice] Gatekeeper config - solution for Single trunk, no BW CLI, no location, one call in sub and redundancy over PSTN

2009-04-07 Thread Prabahar M
Hi, Here is what I tried and it works. Regards, Prabahar . Only one call allowed from CCM to CME over GK . First call from CCM should use the subscriber . Second call from CCM should use PSTN if already a call on subscriber . While a call on subscriber, a call from CME should use publisher .