Hi experts
I am trying to practise different scenario with H323 gateways and
gatekeepers.
Does anyone have any good reference to read those output from debug h225
asn1 ??
Thanks
___
For more information regarding industry leading CCIE
Dear All;
I have 2 requirements and I don't know which one is the correct
configuration..
1. For SIte C CME gateway
Configure SIteC Router as H323 gateway.
Make sure that all inbound outbound H323 traffic is
sourced from the local interface
Anyone know the fastest way to add a bunch of users to a Distro List with in
Unity 5.0? ___
For more information regarding industry leading CCIE Lab training, please visit
www.ipexpert.com
Are you a CCNP or
Hi
I am trying to work out the meaning of these “terminationcause” from the DRQ.
They are in the form of 08028081 or 08028091, is there anywhere I can find out
the meaning of these code?
Thanks
From: Amit Singh [mailto:batraji...@yahoo.com]
Sent: Tuesday, October 04, 2011 6:32 PM
Hi,
In WB 1 Question 9.2 asks us that in incoming call, into the AA 3500, should
be redirected to 3001 after 90 Sec. of Ringing. I configured the BACD
according to the PG but the call will be redirected after approx.. 3 Min and
not after 90 Sec.
Here is the relevant configuration:
Hi Larry:
I finally have my pstn phone configured with the proper settings and load.
I have two routers connected to my 3550 switch. One is HQ and other is the
PSTN router.
HQ-3550
-
interface FastEthernet0/1
description HQ router connected to 3550
switchport trunk
In h323 only one interface can be used as source IP for all h323 messages. You
cant have two h323 sources in same router. Maybe typo error
Regards,
Mohammed Al Baqari
Sent from my iPhone
On Oct 4, 2011, at 12:12 PM, darshan ccievoice0...@hotmail.com wrote:
Dear All;
I have 2
Yes Mohd this is right..but In SiteC CME gateway it asks for Vlan 502 IP and
gatekeeper to use local loopback..so I am really confused.
Regards
Darsh
From: Mohd Baqari [mailto:baqari.voic...@gmail.com]
Sent: Tuesday, October 04, 2011 4:37 PM
To: darshan
Cc:
Hi Robert
I think that your
param max-time-call-retry 9
should be
param max-time-call-retry 90
kind regards
Stuart
From: ccie_voice-boun...@onlinestudylist.com
[mailto:ccie_voice-boun...@onlinestudylist.com] On Behalf Of Robert Schuknecht
Sent: 04 October 2011 13:30
To:
Hi Robert,
Is 3210 a pilot point in a hunt group that has a final parameter set to 3001
also?
If so, I believe that this conflicts with your B-ACD so try removing the final
parameter from your hunt group.
Vik mentions something along these lines in an blog on B-ACD on IPX website,
Kind
Hi Stuart,
yes, the command param max-time-call-retry 9 was a copy/paste error. In
the RTR config it is stated as param max-time-call-retry 90. But, the call
redirect takes place only after a few minutes as opposed to 90 Sec.
/Robert
Von: Geoghegan, Stuart
Hello,
Anyone doing labs now? Are you guys being able to communicate with your call
manager servers? I can ping them from the routers but not from my local
machine... :-/ (not again...)
I was able to communicate with it earlier in my session. I didn't change any
configurations after I was done
Did you do a gateway in config mode on the branch rtr? Is it registered?
Randall
Sent from my iPhone
On Oct 4, 2011, at 1:12 AM, darshan ccievoice0...@hotmail.com wrote:
Dear All;
I have 2 requirements and I don’t know which one is the correct
configuration..
1. For
Hi,
Change param max-time-call-retry 9 to param max-time-call-retry 90 and
it should work as expected.
If you set parameter value which is out of range (I think 60 is
minimum for param
max-time-call-retry) it uses default value.
--
Regards,
Bartosz
2011/10/4 Robert Schuknecht rschukne...@gmx.de
Hi,
thanks to all who have responded. I did some more testing and some more
reading. I found out that the command param max-time-call-retry 90 takes
only place when the Hunt-Group phones are currently busy. If they are
ringing and the call gets back to the script because of no answer, the call
Hi All,
I appeared lab exam last week my result was fail.I just want to know that
what are the fine tuning we have to do to fulfill CISCO requirement.
In Media Resources section i got 3 question i fulfill the requirements . I
got 40 % on that section .
please advise the best practices
I have a hardware solution and I was in yesterday and today with no problems
Randall
Sent from my iPhone
On Oct 3, 2011, at 8:48 PM, pithog...@yahoo.com wrote:
Hi experts,
Here is experience I keep seeing mails that the proctor labs issue has been
fixed but the experience remains the
Guys ,
the h323 bind command is not a GK command , its for the H323 GW so you
can have GK on interface and have the normal config of the GK
and the H323 bind under the interface which will work as H323 GW with the ccm
H323 bind can be usefull if you have Q said bind all media and
signalling to
18 matches