Hi Jon
Ambiguous phrasing, perhaps - the detector has a maximum count rate, as events
per second, and it is easy to exceed this with a good quality small molecule
crystal on an undulator beamline thus under record the intensity of strong
reflections
Best wishes Graeme
On 8 Jun 2020, at
Re: "it turns out to be very very easy to exceed the count rate where the detector electronics can keep up."Sorry if this is obvious, but I take it you mean "_can't_" keep up?Jon CooperOn 4 Jun 2020 13:06, "Winter, Graeme (DLSLtd,RAL,LSCI)" wrote:
Dear All,
A small word of caution regarding
>>> Michael Weyand 06/08/20 12:40 PM >>>
Dear CCP4I2 experts,
I'm trying to submit remote jobs via SSH within CCP4i2. Unfortunately,
we use a non standard SSH port.
So far, I'm not able to add any option within the CCP4I2 interface. For
job submission, I need something to do like
'ssh -p
I tend to agree - though I am still using a 15” machine myself - the lab has
13” machines and at their desks they have a big monitor as well.
Adrian
> On 8 Jun 2020, at 17:37, Harry Powell - CCP4BB
> <193323b1e616-dmarc-requ...@jiscmail.ac.uk> wrote:
>
> Hi
>
> I’d make the decision
Dear Michael,
I've been playing around a bit with remote job submission via SSH in
CCP4 7.0. I remember I had to patch some files and upgraded a python lib
to add support for ED25519 keys and to allow passing non-standard ports
through the GUI. I never got around to wrap this up and forward
Dear CCP4I2 experts,
I'm trying to submit remote jobs via SSH within CCP4i2. Unfortunately,
we use a non standard SSH port.
So far, I'm not able to add any option within the CCP4I2 interface. For
job submission, I need something to do like
'ssh -p X -Y . ccp4i-specific-command ...'.
Is
Hi
I’d make the decision based largely on where I was going to use it, and how
much I was going to have to carry it (and if I ever wanted to use it in coach
class). If it was going to be my machine for “on the road”, I’d go for the 13”
one, but if it was going to sit on my desk most of the
Make sure the 13” display is large enough to display all the GUIs for program
suites that you are interested in.
For example, in the past, the 13” Mac laptops couldn’t display the HKL2000 GUI.
Requirements are found here:
https://hkl-xray.com/hardware-operating-systems
Diana
Finally looking to replace my 2014 Mac Pro lap (duo core; 16 gb RAM. I
would welcome any input or being put in the direction of some related to
the following:
13" versus 16"
I know the 16" has a better and standalone GPU. Is there anyone using a
13" that finds that it works well? If so, what
BEGIN:VCALENDAR
METHOD:CANCEL
PRODID:Microsoft Exchange Server 2010
VERSION:2.0
BEGIN:VTIMEZONE
TZID:Central Standard Time
BEGIN:STANDARD
DTSTART:16010101T02
TZOFFSETFROM:-0500
TZOFFSETTO:-0600
RRULE:FREQ=YEARLY;INTERVAL=1;BYDAY=1SU;BYMONTH=11
END:STANDARD
BEGIN:DAYLIGHT
BEGIN:VCALENDAR
METHOD:REQUEST
PRODID:Microsoft Exchange Server 2010
VERSION:2.0
BEGIN:VTIMEZONE
TZID:Central Standard Time
BEGIN:STANDARD
DTSTART:16010101T02
TZOFFSETFROM:-0500
TZOFFSETTO:-0600
RRULE:FREQ=YEARLY;INTERVAL=1;BYDAY=1SU;BYMONTH=11
END:STANDARD
BEGIN:DAYLIGHT
Dear Jesus, you should look at
https://www.rappsilberlab.org/software/
or
https://www.maxquant.org/
Altough there have been huge strides in recent years in software
development, XL-MS data processing need still some effort.
Br, Georg.
Am 2020-06-08 um 9:48 AM schrieb JESUS BALTANAS
Cryo-EM for Drug Discovery | June 16, 2020
What if you could get structural insights at near-atomic resolution of
your most challenging drug targets at a pace that meets that of your
drug discovery projects?
>From around the world you are invited to join Thermo Fisher Scientific
for Cryo-EM
Well - there is a CCP4 program seqwt which will give the molecular weight
of the given sequence (s).
You say you know the molecular weight of the crosslink and of the whole
complex..
But then I dont know of any software which can predict the composition - I
think you will have to do the arithmetic
Hi all!
I am new in crosslinking,
We performed in our group some time ago crosslinking, and need help
with the data processing.
We only have available the molecular weight of the crosslinked
peptides, so the idea would be to find a free sofware in which you
could enter the whole
The Multiscale Research Institute for Complex Systems (MRICS) at Fudan
University is located at the Zhangjiang Campus of Fudan University and is
supported by the Shanghai High-level Talents Program. MRICS is strongly
committed to the development of novel and effective multi-scale imaging
16 matches
Mail list logo