Re: [ccp4bb] Rpim and how its related to anomalous signal

2012-11-02 Thread Jim Pflugrath
In my opinion Rpim is not related directly to anomalous signal, so perhaps that 
is why there is some confusion.

Also I think some folks confused Rpim with Rrim.  The latter is also called 
Rmeas.  But once again, these are not related directly to anomalous signal.  I 
do not find Rpim very useful for anything since when the data has high 
multiplicity Rpim gets very low, but as Michael Blum told me, "Precision does 
not trump accuracy."  I would personally rather have accurate data than highly 
redundant but inaccurate data.

I like to look at the deltaF / sigma(deltaF) value reported by SHELXC and other 
programs, where deltaF is ||F+| - |F-||.
This might also be called .  There are other things to look at as well.

Jim

From: CCP4 bulletin board [CCP4BB@JISCMAIL.AC.UK] on behalf of Vijayakumar.B 
[vijaybioscie...@gmail.com]
Sent: Tuesday, September 18, 2012 4:36 AM
To: CCP4BB@JISCMAIL.AC.UK
Subject: [ccp4bb] Rpim and how its related to anomalous signal

Dear CCP4BB users,

I am very much interested to work in Anomalous scattering technique for 
macromolecular structure determination. I have already gone through some 
literature in which they have explained about a parameter called “Rpim”.  I am 
little bit confused about Rpim values.

Can anyone tell me about the use of this parameter in structure determination 
by anomalous techniques and how Rpim is related to anomalous signal?  Thanks in 
advance

With kind regards

B. Vijayakumar




Re: [ccp4bb] Unusually low B factors with phenix

2012-11-02 Thread Pavel Afonine
Joao,

I am using the latest version of phenix 1.8.1-1168


1.8.1-1168 should not have that "problem".

If you suspect there is still a problem, you can send me the data and model
files off list, explain what exactly the problem is, and I will have a look
right away.

FYI: there is Phenix mailing list for Phenix-specific questions, where I
can also explain in great details the behavior with the B-factors you
observe.

All the best,
Pavel


Re: [ccp4bb] Unusually low B factors with phenix

2012-11-02 Thread Joao Dias
Hi,
I am using the latest version of phenix 1.8.1-1168 for the MacOSX and I
see a similar behaviour with the B-factors.
Which version do you suggest to update to?

There might be a problem with over-refinement and one workaround might be
to limit the Rfree-R=0.05, but your Rfree will likely to increase. Your
B-factors will make more sense though.

Cheers,
Joao

On 02/11/2012 10:54, "Jeffrey, Philip D."  wrote:

>That sounds like the bug in Phenix.refine v1.8 that a few of us
>encountered - updating to the latest release will help.
>
>Actually wasn't so much a bug but a "feature", albeit not the best one
>imaginable.  Anyone using older v1.8 versions should update.
>
>---
>Phil Jeffrey
>Princeton
>
>On Nov 2, 2012, at 6:41 AM, "Demetres D. Leonidas"
> wrote:
>
>> Dear Tim,
>>
>> this affects all atoms and yes I did reset the B-factors to 20.00 prior
>>to refinement. I have not tried REFMAC but now I will give it a try
>>since phenix does not seem to do the job.
>>
>> best
>>
>> Demetres
>>
>>
>> On 2/11/2012 1:34 μμ, Tim Gruene wrote:
>>> -BEGIN PGP SIGNED MESSAGE-
>>> Hash: SHA1
>>>
>>> Dear Demetres,
>>>
>>> does this affect all atoms, or only a few selected ones?
>>>
>>> Did you compare with refmac5 (for e.g. input script errors), or did
>>> you reset the B-factors to a reasonable value (e.g. 20-30) prior to
>>> refinement? pdbset can do this conveniently.
>>>
>>> Best,
>>> Tim
>>>
>>> On 11/02/2012 11:06 AM, Demetres D. Leonidas wrote:
 Hello,

 I am experiencing a weird problem with B factor refinement
 (individual, isotropic) in phenix.refine (1.8.1.-1168) and  a
 structure at 1.9 A resolution. The ADP values after the refinement
 are very very low, less than 2 and sometimes 0. I am getting the
 same result with and without optimization of the X-ray/ADP weight.
 Has anyone else noticed that and is there a workaround ?

 Demetres

>>> - -- Dr Tim Gruene
>>> Institut fuer anorganische Chemie
>>> Tammannstr. 4
>>> D-37077 Goettingen
>>>
>>> GPG Key ID = A46BEE1A
>>> -BEGIN PGP SIGNATURE-
>>> Version: GnuPG v1.4.12 (GNU/Linux)
>>> Comment: Using GnuPG with Mozilla - http://enigmail.mozdev.org/
>>>
>>> iD8DBQFQk6+vUxlJ7aRr7hoRAvCZAKDxzmLYV74HKanTuoNiqLEu6AmlRwCgkVQs
>>> Q+SZVN6ISb0X38ZekG119/s=
>>> =xKhB
>>> -END PGP SIGNATURE-
>>
>> --
>> ---
>> Dr. Demetres D. Leonidas
>> Associate Professor of Biochemistry
>> Department of Biochemistry & Biotechnology
>> University of Thessaly
>> 26 Ploutonos Str.
>> 41221 Larissa, Greece
>> -
>> Tel. +302410 565278
>> Tel. +302410 565297 (Lab)
>> Fax. +302410 565290
>> E-mail: ddleoni...@bio.uth.gr
>> http://www.bio.uth.gr
>> ---
>



Contact and registered office address: Heptares Therapeutics Limited, BioPark, 
Broadwater Road, Welwyn Garden City, Hertfordshire, AL7 3AX. The information in 
this e-mail is confidential and may
be legally privileged. It is intended for the exclusive attention of the 
addressee stated above and should not be copied or disclosed to any other. If 
you have received this transmission in error, please make no use of its 
contents and contact the sender.


Re: [ccp4bb] Unusually low B factors with phenix

2012-11-02 Thread Jeffrey, Philip D.
That sounds like the bug in Phenix.refine v1.8 that a few of us encountered - 
updating to the latest release will help.

Actually wasn't so much a bug but a "feature", albeit not the best one 
imaginable.  Anyone using older v1.8 versions should update.

---
Phil Jeffrey
Princeton

On Nov 2, 2012, at 6:41 AM, "Demetres D. Leonidas"  
wrote:

> Dear Tim,
> 
> this affects all atoms and yes I did reset the B-factors to 20.00 prior to 
> refinement. I have not tried REFMAC but now I will give it a try since phenix 
> does not seem to do the job.
> 
> best
> 
> Demetres
> 
> 
> On 2/11/2012 1:34 μμ, Tim Gruene wrote:
>> -BEGIN PGP SIGNED MESSAGE-
>> Hash: SHA1
>> 
>> Dear Demetres,
>> 
>> does this affect all atoms, or only a few selected ones?
>> 
>> Did you compare with refmac5 (for e.g. input script errors), or did
>> you reset the B-factors to a reasonable value (e.g. 20-30) prior to
>> refinement? pdbset can do this conveniently.
>> 
>> Best,
>> Tim
>> 
>> On 11/02/2012 11:06 AM, Demetres D. Leonidas wrote:
>>> Hello,
>>> 
>>> I am experiencing a weird problem with B factor refinement
>>> (individual, isotropic) in phenix.refine (1.8.1.-1168) and  a
>>> structure at 1.9 A resolution. The ADP values after the refinement
>>> are very very low, less than 2 and sometimes 0. I am getting the
>>> same result with and without optimization of the X-ray/ADP weight.
>>> Has anyone else noticed that and is there a workaround ?
>>> 
>>> Demetres
>>> 
>> - -- Dr Tim Gruene
>> Institut fuer anorganische Chemie
>> Tammannstr. 4
>> D-37077 Goettingen
>> 
>> GPG Key ID = A46BEE1A
>> -BEGIN PGP SIGNATURE-
>> Version: GnuPG v1.4.12 (GNU/Linux)
>> Comment: Using GnuPG with Mozilla - http://enigmail.mozdev.org/
>> 
>> iD8DBQFQk6+vUxlJ7aRr7hoRAvCZAKDxzmLYV74HKanTuoNiqLEu6AmlRwCgkVQs
>> Q+SZVN6ISb0X38ZekG119/s=
>> =xKhB
>> -END PGP SIGNATURE-
> 
> -- 
> ---
> Dr. Demetres D. Leonidas
> Associate Professor of Biochemistry
> Department of Biochemistry & Biotechnology
> University of Thessaly
> 26 Ploutonos Str.
> 41221 Larissa, Greece
> -
> Tel. +302410 565278
> Tel. +302410 565297 (Lab)
> Fax. +302410 565290
> E-mail: ddleoni...@bio.uth.gr
> http://www.bio.uth.gr
> ---


Re: [ccp4bb] Unusually low B factors with phenix

2012-11-02 Thread George Sheldrick
It could be a problem with your data, e.g. many overloaded reflections 
not being removed or F and F^2 mixed up. What is your Wilson B-value?


George

--
Prof. George M. Sheldrick FRS
Dept. Structural Chemistry,
University of Goettingen,
Tammannstr. 4,
D37077 Goettingen, Germany
Tel. +49-551-39-3021 or -3068
Fax. +49-551-39-22582


Re: [ccp4bb] Unusually low B factors with phenix

2012-11-02 Thread Demetres D. Leonidas

Dear Tim,

this affects all atoms and yes I did reset the B-factors to 20.00 prior 
to refinement. I have not tried REFMAC but now I will give it a try 
since phenix does not seem to do the job.


best

Demetres


On 2/11/2012 1:34 μμ, Tim Gruene wrote:

-BEGIN PGP SIGNED MESSAGE-
Hash: SHA1

Dear Demetres,

does this affect all atoms, or only a few selected ones?

Did you compare with refmac5 (for e.g. input script errors), or did
you reset the B-factors to a reasonable value (e.g. 20-30) prior to
refinement? pdbset can do this conveniently.

Best,
Tim

On 11/02/2012 11:06 AM, Demetres D. Leonidas wrote:

Hello,

I am experiencing a weird problem with B factor refinement
(individual, isotropic) in phenix.refine (1.8.1.-1168) and  a
structure at 1.9 A resolution. The ADP values after the refinement
are very very low, less than 2 and sometimes 0. I am getting the
same result with and without optimization of the X-ray/ADP weight.
Has anyone else noticed that and is there a workaround ?

Demetres

- -- 
Dr Tim Gruene

Institut fuer anorganische Chemie
Tammannstr. 4
D-37077 Goettingen

GPG Key ID = A46BEE1A
-BEGIN PGP SIGNATURE-
Version: GnuPG v1.4.12 (GNU/Linux)
Comment: Using GnuPG with Mozilla - http://enigmail.mozdev.org/

iD8DBQFQk6+vUxlJ7aRr7hoRAvCZAKDxzmLYV74HKanTuoNiqLEu6AmlRwCgkVQs
Q+SZVN6ISb0X38ZekG119/s=
=xKhB
-END PGP SIGNATURE-


--
---
Dr. Demetres D. Leonidas
Associate Professor of Biochemistry
Department of Biochemistry & Biotechnology
University of Thessaly
26 Ploutonos Str.
41221 Larissa, Greece
-
Tel. +302410 565278
Tel. +302410 565297 (Lab)
Fax. +302410 565290
E-mail: ddleoni...@bio.uth.gr
http://www.bio.uth.gr
---


Re: [ccp4bb] Unusually low B factors with phenix

2012-11-02 Thread Tim Gruene
-BEGIN PGP SIGNED MESSAGE-
Hash: SHA1

Dear Demetres,

does this affect all atoms, or only a few selected ones?

Did you compare with refmac5 (for e.g. input script errors), or did
you reset the B-factors to a reasonable value (e.g. 20-30) prior to
refinement? pdbset can do this conveniently.

Best,
Tim

On 11/02/2012 11:06 AM, Demetres D. Leonidas wrote:
> Hello,
> 
> I am experiencing a weird problem with B factor refinement
> (individual, isotropic) in phenix.refine (1.8.1.-1168) and  a
> structure at 1.9 A resolution. The ADP values after the refinement
> are very very low, less than 2 and sometimes 0. I am getting the
> same result with and without optimization of the X-ray/ADP weight.
> Has anyone else noticed that and is there a workaround ?
> 
> Demetres
> 

- -- 
Dr Tim Gruene
Institut fuer anorganische Chemie
Tammannstr. 4
D-37077 Goettingen

GPG Key ID = A46BEE1A
-BEGIN PGP SIGNATURE-
Version: GnuPG v1.4.12 (GNU/Linux)
Comment: Using GnuPG with Mozilla - http://enigmail.mozdev.org/

iD8DBQFQk6+vUxlJ7aRr7hoRAvCZAKDxzmLYV74HKanTuoNiqLEu6AmlRwCgkVQs
Q+SZVN6ISb0X38ZekG119/s=
=xKhB
-END PGP SIGNATURE-


[ccp4bb] Unusually low B factors with phenix

2012-11-02 Thread Demetres D. Leonidas

Hello,

I am experiencing a weird problem with B factor refinement (individual, 
isotropic) in phenix.refine (1.8.1.-1168) and  a structure at 1.9 A 
resolution. The ADP values after the refinement are very very low, less 
than 2 and sometimes 0. I am getting the same result with and without 
optimization of the X-ray/ADP weight. Has anyone else noticed that and 
is there a workaround ?


Demetres

--
---
Dr. Demetres D. Leonidas
Associate Professor of Biochemistry
Department of Biochemistry & Biotechnology
University of Thessaly
26 Ploutonos Str.
41221 Larissa, Greece
-
Tel. +302410 565278
Tel. +302410 565297 (Lab)
Fax. +302410 565290
E-mail: ddleoni...@bio.uth.gr
http://www.bio.uth.gr
---