On Fri, Aug 19, 2016 at 1:00 AM, Huw Davies
wrote:
>
>> On 19 Aug 2016, at 02:31, shad wrote:
>>
>> It seems that copies of this software are really difficult to find, but a
>> complete copy
>> was available on the latrobe ftp DEC Rainbow archive... which disappeared
>> with all valuable da
On 08/20/2016 02:40 AM, Warner Losh wrote:
On Fri, Aug 19, 2016 at 1:00 AM, Huw Davies
wrote:
On 19 Aug 2016, at 02:31, shad wrote:
It seems that copies of this software are really difficult to find, but a
complete copy
was available on the latrobe ftp DEC Rainbow archive... which disa
> On Fri, Aug 19, 2016 at 5:56 PM, Steven M Jones wrote:
> > Models Display Resolution Planes Processor Coprocessor
> > -- --- -- -- - ---
> > 700/X Grayscale 19" 1024x768 834010/60MHz 80186/16MHz
> > 700/X VGA C
I have same problem here
we have the large size calcomp early plotter that actually has an ibm
tag on it!
it came to us with a hp 3000 series 3 with a parallel interface board
for the 3000... I used to enjoy playing with it.
back in the days when museum was in a suite next
On 08/20/2016 09:06 AM, tony duell wrote:
Somewhere I have a thing badged 'Princeton Ultra-X'. This is a pizza-box type
slab that goes under a VGA montor and links to a keyboard and mouse and is,
of course a standalone Xterminal.
It uses an 80188 for I/O (including 10Mbps ethernet). The Xserver
>> [small pizza-box X terminal]
> I had a similar unit from NCD, [...]
> Back in the day I remember using monochrome NCD X terminals though,
> and those things were just great - it would be nice to find one again
> one day.
I own two NCD X-terminals; if you can drop by Ottawa, I wouldn't mind
unl
Hi there,
I'm still having some glitches with my 6800 system and would like to do a
proper RAM diag. From reading, it seems like CDAT is the most exhaustive.. but
I cannot get it to run. I can load and then run it.. but it immediately fails
at address 8000. Since I understand this is us
On 8/19/2016 6:49 PM, Glen Slick wrote:
Device,Number? dhv11,1
Device,Number? tqk50,1
Device,Number? rqdx3,1
Device,Number? exit
Address/Vector Assignments
-772150/154 RQDX3
-774500/260 TQK50
-760440/300 DHV11
configure
Enter device configuration, HELP, or EXIT
Device,Number? dhv11,1
Device,
Here is the instructions for memory tests, CDAT is on page 3.
http://www.swtpc.com/mholley/swtbug/MemoryDiagnostic.pdf
The CDAT memory diagnostic can be used to help locate memory problems in a
SWTPC 6800 computer system that MEMCON and ROBIT may miss. The program itself
resides entirely within