[ceph-users] Re: OSD upgrades

2020-06-02 Thread Paul Emmerich
Correct, "crush weight" and normal "reweight" are indeed very different. The original post mentions "rebuilding" servers, in this case the correct way is to use "destroy" and then explicitly re-use the OSD afterwards. purge is really only for OSDs that you don't get back (or broken disks that you

[ceph-users] Re: OSD upgrades

2020-06-02 Thread Thomas Byrne - UKRI STFC
As you have noted, 'ceph osd reweight 0' is the same as an 'ceph osd out', but it is not the same as removing the OSD from the crush map (or setting crush weight to 0). This explains your observation of the double rebalance when you mark an OSD out (or reweight an OSD to 0), and then remove it

[ceph-users] Re: OSD upgrades

2020-06-02 Thread Paul Emmerich
"reweight 0" and "out" are the exact same thing Paul -- Paul Emmerich Looking for help with your Ceph cluster? Contact us at https://croit.io croit GmbH Freseniusstr. 31h 81247 München www.croit.io Tel: +49 89 1896585 90 On Tue, Jun 2, 2020 at 9:30 AM Wido den Hollander wrote: > > > On

[ceph-users] Re: OSD upgrades

2020-06-02 Thread Wido den Hollander
On 6/2/20 5:44 AM, Brent Kennedy wrote: > We are rebuilding servers and before luminous our process was: > > > > 1. Reweight the OSD to 0 > > 2. Wait for rebalance to complete > > 3. Out the osd > > 4. Crush remove osd > > 5. Auth del osd > > 6. Ceph