--time_based --group_reporting
--name=journal-test
write: io=1507.4MB, bw=25723KB/s, iops=6430, runt= 60007msec
Also tested a Micron 550 we had sitting around and it maxed out at
2.5mb/s, both results conflict with the chart
Regards,
Cameron Scrace
Infrastructure Engineer
Mobile +64 22 610 4629
Phone
The other option we were considering was putting the journals on the OS
SSDs, they are only 250GB and the rest would be for the OS. Is that a
decent option?
Thanks!
Cameron Scrace
Infrastructure Engineer
Mobile +64 22 610 4629
Phone +64 4 462 5085
Email cameron.scr...@solnet.co.nz
Solnet
to be part of the
cache pool.
2) Put the spinning disk journals on the OS SSDs and use the 2 1TB SSDs
for the cache pool.
In both cases the other 4 1TB SSDs will be part of their own tier.
Thanks a lot!
Cameron Scrace
Infrastructure Engineer
Mobile +64 22 610 4629
Phone +64 4 462 5085
Email
money for the project.
Thanks,
Cameron Scrace
Infrastructure Engineer
Mobile +64 22 610 4629
Phone +64 4 462 5085
Email cameron.scr...@solnet.co.nz
Solnet Solutions Limited
Level 12, Solnet House
70 The Terrace, Wellington 6011
PO Box 397, Wellington 6140
www.solnet.co.nz
From
It mostly like is the model of switch. In its settings the minimum frame
size you can set is 1518, default MTU is 1500, seems the switch wants the
18 byte difference.
We are using a pair of Netgear XS712T and bonded pairs of Intel 10-Gigabit
X540-AT2 (rev 01) with 3 VLans.
Cameron Scrace
to think that the journal and OSD are meant to be on
the same drive.: http://pastebin.com/CEk8Teys
Anyone had this issue before or any suggestions on how to fix it? When I
use a non raided device it works perfectly.
Thanks,
Cameron Scrace
Infrastructure Engineer
Mobile +64 22 610 4629
Phone
Thanks for the links, Jumbo frames are definitely working. Although we had
to set the MTU to 8192 because one of the components doesn't support an
MTU higher than that.
Thanks for the help. Looks like we may just have to deal with jumbo frames
being off.
Cameron Scrace
Infrastructure
Setting the MTU to 1500 worked, monitors reach quorum right away.
Unfortunately we really want Jumbo Frames to be on, any ideas on how to
get ceph to work with them on?
Thanks!
Cameron Scrace
Infrastructure Engineer
Mobile +64 22 610 4629
Phone +64 4 462 5085
Email cameron.scr
) and it still times out.
Thanks!
Cameron Scrace
Infrastructure Engineer
Mobile +64 22 610 4629
Phone +64 4 462 5085
Email cameron.scr...@solnet.co.nz
Solnet Solutions Limited
Level 12, Solnet House
70 The Terrace, Wellington 6011
PO Box 397, Wellington 6140
www.solnet.co.nz
From: Somnath
Seems to be something to do with our switch. If the interface MTU is too
close to the switch MTU it stops working. Thanks for all your help :)
Cameron Scrace
Infrastructure Engineer
Mobile +64 22 610 4629
Phone +64 4 462 5085
Email cameron.scr...@solnet.co.nz
Solnet Solutions Limited
Level
\/0
}
]
}
}
Any suggestions on what could be the issue?
Regards,
Cameron Scrace
Infrastructure Engineer
Mobile +64 22 610 4629
Phone +64 4 462 5085
Email cameron.scr...@solnet.co.nz
Solnet Solutions Limited
Level 12, Solnet House
70 The Terrace, Wellington 6011
PO Box
11 matches
Mail list logo