Hi.

In our ceph cluster we hit one OSD with 95% full while others in same pool
only hit 40% .. (total usage is ~55%). Thus I went into a:

sudo ceph osd reweight-by-utilization 110 0.05 12

Which initated some data movement.. but right after ceph status reported:


jk@bison:~/adm-git$ sudo ceph -s
  cluster:
    id:     dbc33946-ba1f-477c-84df-c63a3c9c91a6
    health: HEALTH_WARN
            49924979/660322545 objects misplaced (7.561%)
            Degraded data redundancy: 26/660322545 objects degraded
(0.000%), 2 pgs degraded

  services:
    mon: 3 daemons, quorum torsk1,torsk2,bison
    mgr: bison(active), standbys: torsk1
    mds: cephfs-1/1/2 up  {0=zebra01=up:active}, 1 up:standby-replay
    osd: 78 osds: 78 up, 78 in; 255 remapped pgs
    rgw: 9 daemons active

  data:
    pools:   16 pools, 2184 pgs
    objects: 141M objects, 125 TB
    usage:   298 TB used, 340 TB / 638 TB avail
    pgs:     26/660322545 objects degraded (0.000%)
             49924979/660322545 objects misplaced (7.561%)
             1927 active+clean
             187  active+remapped+backfilling
             68   active+remapped+backfill_wait
             2    active+recovery_wait+degraded

  io:
    client:   761 kB/s rd, 1284 kB/s wr, 85 op/s rd, 79 op/s wr
    recovery: 623 MB/s, 665 objects/s


Any idea about how those 26 objects got degraded in the process?
Just in-flight writes ?

Any means to priority the 26 objects over the 49M objects that need to be
replaced?

Thanks.