Andrija,
thanks a lot for the useful info!
I would also like to thank Kingrat at the IRC channel for his useful
advice!
I was under the wrong impression that public is the one used for RADOS.
So I thought that public=external=internet and therefore I used that
one in my conf.
I
Andrija,
Thanks for you help!
In my case I just have one 192.* network, so should I put that for
both?
Besides monitors do I have to list OSDs as well?
Thanks again!
Best,
George
This is how I did it, and then retart each OSD one by one, but
monritor with ceph -s, when ceph is healthy,
Georgios,
no need to put ANYTHING if you don't plan to split client-to-OSD vs
OSD-OSD-replication on 2 different Network Cards/Networks - for pefromance
reasons.
if you have only 1 network - simply DONT configure networks at all inside
your CEPH.conf file...
if you have 2 x 1G cards in servers,