Matt, Thank you very much!
Matt Benjamin 于2018年10月24日周三 下午8:16写道:
> We recommend disabling dynamic resharding until fixes for two known
> issues, plus a radosgw-admin command to remove traces of old dynamic
> reshard runs, land in master and Luminous (shortly for at least the
> first of these
We recommend disabling dynamic resharding until fixes for two known
issues, plus a radosgw-admin command to remove traces of old dynamic
reshard runs, land in master and Luminous (shortly for at least the
first of these fixes).
Matt
On Wed, Oct 24, 2018 at 6:46 AM, Ch Wan wrote:
> Hi. I
Hi. I encounter this problem these days.
The clients get timeout exception while rgw doing resharding.
Could we decrease the impact of dynamic resharding by adjusting some
configurations, or just increase the timeout threshold at client-side?
Jakub Jaszewski 于2018年7月16日周一 下午11:25写道:
> Hi,
> We
Hi,
We run 5 RADOS Gateways on Luminous 12.2.5 as upstream servers in nginx
active-active setup, based on keepalived.
Cluster is 12x Ceph nodes (16x 10TB OSD(bluestore) per node, 2x 10Gb
network link shared by access and cluster networks), RGW pool is EC 9+3.
We recently noticed below entries in