Re: [chrony-users] All network sources unusable

2023-06-05 Thread Torsten Wolf
Apologies, Denny! I am unhappy myself that I do not respect the simplest mailing list etiquette such as fixed width font, sensitive line wrap and encoding since I switched to MacOS and Postbox. I guess it's time to get mutt up and running like in the old Linux days... Back on topic - I hope

Re: [chrony-users] All network sources unusable

2023-06-05 Thread Torsten Wolf
That was the hint I needed! The main router the RasPi is connected to also runs chrony and acts as the timeserver for all local network clients. However, the script managing that chrony instance had an option to redirect all NTP traffic through the router. Interesting that I did not find that

Re: [chrony-users] All network sources unusable

2023-06-05 Thread Denny Page
I’m sorry, unlike your prior email, I am unable to read the output in your last email. Your prior email looked like this: —— $ chronyc sourcestats Name/IP AddressNP NR Span Frequency Freq Skew Offset Std Dev

Re: [chrony-users] All network sources unusable

2023-06-05 Thread Miroslav Lichvar
On Sun, Jun 04, 2023 at 12:07:44PM +0200, Torsten Wolf wrote: > Not sure why the Reach value for the PPS source is 113. A few minuts later > that value increased to 372, just to go down again afterwards. That might be due to changing offset between GPS and PPS. Try adjusting the offset option to

Re: [chrony-users] All network sources unusable

2023-06-04 Thread Torsten Wolf
I added "noselect" to the NMEA (SHM0) source and restarted chrony. After an hour the output is $ chronyc -m sources sourcestats MS Name/IP address Stratum Poll Reach LastRx Last sample === #? GPS 

Re: [chrony-users] All network sources unusable

2023-06-03 Thread Denny Page
Try this: chronyc -m sources sourcestats This will print the sources and then the source stats. I suspect that the other sources you have are not actually being polled or are not reachable. Check the “Reach” column in sources. Denny > On Jun 3, 2023, at 14:31, Torsten Wolf wrote: > >

Re: [chrony-users] All network sources unusable

2023-06-03 Thread Torsten Wolf
Bryan, many thanks for the explanation and the suggestion regarding SHM0. My only worry is that the sourcestats output is not offering much in terms of offset of the network sources: $ chronyc sourcestats Name/IP Address    NP  NR  Span  Frequency  Freq Skew  Offset  Std Dev

Re: [chrony-users] All network sources unusable

2023-06-03 Thread Bryan Christianson
Hi Torsten From the chrony.conf(5) manpage: noselect Never select this source. This is useful for monitoring or with sources which are not very accurate, but are locked with a PPS refclock. Your 'noselect' hosts are not viable sources as they will never be selected. They will however show up