CUCM/IM v 11.5.SU9
CUC - v 12.5 SU4
I need to update our DNS server ip's to have a different secondary address. The
research I have done leads me to believe I need to restart the server after
making this change. This seems excessive, but in line with Cisco Collab OS.
Has anyone on similar
loose calls? I run a 1006 so calls are
never dropped. Just wondered if the HA for cube shares the call state info
should a failover happen.
On 2/4/22 7:05 AM, Riley, Sean via cisco-voip wrote:
Update on this. We have a CUBE HA Pair at one of our sites. We had a fail
over event last
with the following gateway configurations, as
most of you probably already know.
gateway
media-inactivity-criteria all
timer receive-rtcp 10
timer receive-rtp 86400
Thanks.
From: cisco-voip On Behalf Of Riley, Sean
via cisco-voip
Sent: Thursday, February 3, 2022 11:14 AM
To: cisco-voip
Unity v 12.5 SU4 with no changes recently and 300 second max message length.
Voice gateways are CUBEs running isr4300-universalk9.16.09.08.SPA.bin with no
changes recently. 2 separate sites having same issue. Internal calls to
voicemail are fine.
We just had this reported yesterday and I can