On Wed, 2008-10-29 at 11:22 -0500, David Teigland wrote:
On Wed, Oct 29, 2008 at 11:12:41AM -0500, Kevin Anderson wrote:
Hi all,
Recently we had cluster customer where the fencing agent successfully
powered off a node, but the script failed to power the node back on due
to firmware
On Wed, Oct 29, 2008 at 11:12:41AM -0500, Kevin Anderson wrote:
Hi all,
Recently we had cluster customer where the fencing agent successfully
powered off a node, but the script failed to power the node back on due
to firmware changes on the fencing device.
Question is whether we should