The bug seems to be still alive with the recent framework version
(5.49.0-1) with plasma-desktop/-workspace 4:5.13.5-1+b1.
On my workstation (5 days uptime, at the moment), the OOM's kill pretty
much everything, including Kwin.
I can recover the system by restarting plasma, but not everything can
Package: system-config-printer-kde
Version: 4:4.8.4-3
Severity: grave
Justification: renders package unusable
Dear Maintainer,
when installing the package, a critical dependency (cups) is missing.
# apt-get install system-config-printer-kde
[..]
$ kcmshell4 system-config-printer-kde
a VM to see if I can catch it with
more details (and snapshots, maybe?).
Thanks for the reply.
S.
On Mon, Apr 22, 2013 at 10:06 PM, Christian PERRIER bubu...@debian.org wrote:
severity 705971 normal
thanks
Quoting Stefano Forli (ntro...@gmail.com):
Package: debian-installer
Version
Package: debian-installer
Version: 20130415
Severity: critical
Tags: installation, wheezy, console-setup
It seems that if a TTY console is in use during the installation, the
whole installation process hangs and can't be recovered (see below).
It is possible to switch to different tty's, but It
Package: fail2ban
Version: 0.8.4-3+squeeze1
Severity: normal
When parsing a jail.local config file there is a problem when parsing inline
comments with #.
For example the following line in the jail.local file:
bantime = 28800 # seconds
results in an error message when checking the
/6ad4276a4eaf095dd6408122d729fcb1321bd029
with which I will close this bug whenever freshier f2b gets uploaded
Cheers,
On Mon, 04 Jun 2012, Stefano Forli wrote:
Package: fail2ban
Version: 0.8.4-3+squeeze1
Severity: normal
When parsing a jail.local config file there is a problem when parsing inline
Package: audacious
Version: 2.3-2
Severity: minor
The option to show the GUI on all workspaces stops working after some time of
usage, and requires to be re-set.
I've tested activating the option via the Gnome panel (right-mouse-button -
Always on visible workspace) and via Audacious menu
Package: pymol
Version: 0.98+0.99rc6-2
Severity: normal
*** Please type your report below this line ***
-When clicking on the Builder button on the toolbar, an error is given:
Error: 1
KeyError Exception in Tk callback
Function: function lambda at 0x2bcd2758 (type: type
'function')
Package: pymol
Version: 0.98+0.99rc6-2
Severity: normal
Because of a wrong path definition in the
/usr/share/python-support/pymol/pymol/fitting.py:64 file, is not
possible to perform any alignment using the BLOSUM62 matrix.
The error reported by Pymol is :
Match-Error: unable to open matrix
9 matches
Mail list logo