Bug#579252: geeqie: Extracted thumbs from Olympus E-500 raw files are so small

2010-05-06 Thread Michal Čihař
Hi

Dne Mon, 26 Apr 2010 15:41:43 +0200
Celso González ce...@mitago.net napsal(a):

 When displaying raw images taken with an Olympus E-500 camera (.orf format) 
 the
 extracted thumb shown has 160*120 size.
 If I try to extract the thumb with dcraw -e it gets an usable thumbnail of 
 1600x1200,
 just 10 times bigger (hint?)
 
 Raw images taken with an Olympus E-510, also .orf format but seems its a 
 diferent one,
 are shown with normal 1600x1200 size.

Can you please provide some sample image which shows this bug? Anyway
it will most likely be a bug in exiv2 library, which geeqie uses for
parsing raw files.

-- 
Michal Čihař | http://cihar.com | http://blog.cihar.com


signature.asc
Description: PGP signature


Bug#579252: geeqie: Extracted thumbs from Olympus E-500 raw files are so small

2010-05-06 Thread Michal Čihař
Hi

Dne Thu, 6 May 2010 10:39:10 +0200
Celso González ce...@mitago.net napsal(a):

 Sure
 
 You can download 2 samples from
 http://mitago.net/tmp/Olympus_E500.orf
 http://mitago.net/tmp/Olympus_E510.orf
 
 And yes, it looks like an exiv2 problem, so if you prefer you may forward the 
 bug

Okay, forwarding the bug to exiv2.

-- 
Michal Čihař | http://cihar.com | http://blog.cihar.com


signature.asc
Description: PGP signature


Bug#579252: geeqie: Extracted thumbs from Olympus E-500 raw files are so small

2010-05-06 Thread Celso González
On Thu, May 06, 2010 at 09:22:11AM +0200, Michal Čihař wrote:
 Dne Mon, 26 Apr 2010 15:41:43 +0200
 Celso González ce...@mitago.net napsal(a):
 
  When displaying raw images taken with an Olympus E-500 camera (.orf format) 
  the
  extracted thumb shown has 160*120 size.
  If I try to extract the thumb with dcraw -e it gets an usable thumbnail of 
  1600x1200,
  just 10 times bigger (hint?)
  
  Raw images taken with an Olympus E-510, also .orf format but seems its a 
  diferent one,
  are shown with normal 1600x1200 size.
 
 Can you please provide some sample image which shows this bug? Anyway
 it will most likely be a bug in exiv2 library, which geeqie uses for
 parsing raw files.

Sure

You can download 2 samples from
http://mitago.net/tmp/Olympus_E500.orf
http://mitago.net/tmp/Olympus_E510.orf

And yes, it looks like an exiv2 problem, so if you prefer you may forward the 
bug

$exiv2 -pp Olympus_E500.orf
Olympus_E500.orf  Preview 1: image/jpeg, 160x120 pixels, 10167 bytes
Olympus_E500.orf  Preview 2: image/jpeg, 160x120 pixels, 10167 bytes 
 
 No big preview


$exiv2 -pp Olympus_E500.orf
Olympus_E510.orf  Preview 1: image/jpeg, 160x120 pixels, 8295 bytes
Olympus_E510.orf  Preview 2: image/jpeg, 1600x1200 pixels, 394571 bytes

If I try with exiftool, it shows the correct ones
$ exiftool Olympus_E500.orf | grep Preview
Preview Image Valid : Yes
Preview Image Start : 24576
Preview Image Length: 417457
Preview Image   : (Binary data 417457 bytes, use -b option to 
extract)

$ exiftool Olympus_E510.orf | grep Preview
Preview Image Valid : Yes
Preview Image Start : 24576
Preview Image Length: 394571
Preview Image   : (Binary data 394571 bytes, use -b option to 
extract)

Thanks in advance

-- 
Celso González (PerroVerd)
http://mitago.net



--
To UNSUBSCRIBE, email to debian-bugs-dist-requ...@lists.debian.org
with a subject of unsubscribe. Trouble? Contact listmas...@lists.debian.org



Bug#579252: geeqie: Extracted thumbs from Olympus E-500 raw files are so small

2010-05-06 Thread Michal Čihař
Hi again

Created upstream bug:

http://dev.exiv2.org/issues/show/703

Dne Thu, 6 May 2010 10:39:10 +0200
Celso González ce...@mitago.net napsal(a):

 Sure
 
 You can download 2 samples from
 http://mitago.net/tmp/Olympus_E500.orf
 http://mitago.net/tmp/Olympus_E510.orf
 
 And yes, it looks like an exiv2 problem, so if you prefer you may forward the 
 bug
 
 $exiv2 -pp Olympus_E500.orf
 Olympus_E500.orf  Preview 1: image/jpeg, 160x120 pixels, 10167 bytes
 Olympus_E500.orf  Preview 2: image/jpeg, 160x120 pixels, 10167 bytes 
  
  No big preview
 
 
 $exiv2 -pp Olympus_E500.orf
 Olympus_E510.orf  Preview 1: image/jpeg, 160x120 pixels, 8295 bytes
 Olympus_E510.orf  Preview 2: image/jpeg, 1600x1200 pixels, 394571 bytes
 
 If I try with exiftool, it shows the correct ones
 $ exiftool Olympus_E500.orf | grep Preview
 Preview Image Valid : Yes
 Preview Image Start : 24576
 Preview Image Length: 417457
 Preview Image   : (Binary data 417457 bytes, use -b option to 
 extract)
 
 $ exiftool Olympus_E510.orf | grep Preview
 Preview Image Valid : Yes
 Preview Image Start : 24576
 Preview Image Length: 394571
 Preview Image   : (Binary data 394571 bytes, use -b option to 
 extract)

-- 
Michal Čihař | http://cihar.com | http://blog.cihar.com


signature.asc
Description: PGP signature


Bug#579252: geeqie: Extracted thumbs from Olympus E-500 raw files are so small

2010-04-26 Thread Celso González
Package: geeqie
Version: 1:1.0-1
Severity: normal
Tags: upstream


Hi

When displaying raw images taken with an Olympus E-500 camera (.orf format) the
extracted thumb shown has 160*120 size.
If I try to extract the thumb with dcraw -e it gets an usable thumbnail of 
1600x1200,
just 10 times bigger (hint?)

Raw images taken with an Olympus E-510, also .orf format but seems its a 
diferent one,
are shown with normal 1600x1200 size.

Thanks in advance


-- System Information:
Debian Release: squeeze/sid
  APT prefers unstable
  APT policy: (500, 'unstable'), (101, 'experimental')
Architecture: i386 (i686)

Kernel: Linux 2.6.32-3-686 (SMP w/2 CPU cores)
Locale: LANG=es_ES.UTF-8, LC_CTYPE=es_ES.UTF-8 (charmap=UTF-8)
Shell: /bin/sh linked to /bin/bash

Versions of packages geeqie depends on:
ii  geeqie-common   1:1.0-1  data files for Geeqie
ii  libc6   2.10.2-6 Embedded GNU C Library: Shared lib
ii  libexiv2-6  0.19-1   EXIF/IPTC metadata manipulation li
ii  libgcc1 1:4.4.3-9GCC support library
ii  libglib2.0-02.24.0-1 The GLib library of C routines
ii  libgtk2.0-0 2.20.0-3 The GTK+ graphical user interface
ii  liblcms11.18.dfsg-1.2+b1 Color management library
ii  liblircclient0  0.8.3-5  infra-red remote control support -
ii  libpango1.0-0   1.28.0-1 Layout and rendering of internatio
ii  libstdc++6  4.4.3-9  The GNU Standard C++ Library v3

Versions of packages geeqie recommends:
ii  exiftran 2.07-3  transform digital camera jpeg imag
ii  exiv20.19-1  EXIF/IPTC metadata manipulation to
ii  imagemagick  7:6.6.0.4-2 image manipulation programs
ii  ufraw0.16-1+b1   standalone importer for raw camera
ii  zenity   2.30.0-1Display graphical dialog boxes fro

Versions of packages geeqie suggests:
pn  geeqie-dbgnone (no description available)
ii  gimp  2.6.8-3The GNU Image Manipulation Program
ii  libjpeg-progs 8a-1   Programs for manipulating JPEG fil
pn  xpaintnone (no description available)

-- no debconf information



-- 