Bug#659351: minicom: Minicom stops receiving in -R utf-8 mode

2012-02-11 Thread Adam Lackorzynski
Hi,

On Fri Feb 10, 2012 at 13:01:20 +, Mike Crowe wrote:
 Package: minicom
 Version: 2.4-3
 Severity: normal
 
 LANG=en_GB.utf8
 Minicom parameters -m -c on -8 -R utf-8
 
 If minicom receives an invalid UTF-8 sequence from the serial port it doesn't
 display any more of the characters that have been sent.
 
 For example (borrowing from bug 413934) if the byte sequence f8 e2 82 ac c2 
 a3
 0a is received then no further serial output is displayed.
 
 Steps to reproduce:
 
 Connect via serial to another Linux box and enter something like this at the
 shell:
 
  printf \xf8\xe2\x82\xac\xc2\xa3\nFoo bar baz; ls -lR /
 
 Notice that no more output is seen. Exiting from minicom and relaunching is
 required to see further serial input.

Thanks for the test case, confirmed and fixed upstream, and included in
new version 2.6.1.



Adam
-- 
Adam a...@os.inf.tu-dresden.de
  Lackorzynski http://os.inf.tu-dresden.de/~adam/



-- 
To UNSUBSCRIBE, email to debian-bugs-dist-requ...@lists.debian.org
with a subject of unsubscribe. Trouble? Contact listmas...@lists.debian.org



Bug#659351: minicom: Minicom stops receiving in -R utf-8 mode

2012-02-10 Thread Mike Crowe
Package: minicom
Version: 2.4-3
Severity: normal

LANG=en_GB.utf8
Minicom parameters -m -c on -8 -R utf-8

If minicom receives an invalid UTF-8 sequence from the serial port it doesn't
display any more of the characters that have been sent.

For example (borrowing from bug 413934) if the byte sequence f8 e2 82 ac c2 a3
0a is received then no further serial output is displayed.

Steps to reproduce:

Connect via serial to another Linux box and enter something like this at the
shell:

 printf \xf8\xe2\x82\xac\xc2\xa3\nFoo bar baz; ls -lR /

Notice that no more output is seen. Exiting from minicom and relaunching is
required to see further serial input.



-- System Information:
Debian Release: 6.0.4
  APT prefers proposed-updates
  APT policy: (500, 'proposed-updates'), (500, 'stable')
Architecture: amd64 (x86_64)

Kernel: Linux 3.2.0-0.bpo.1-amd64 (SMP w/4 CPU cores)
Locale: LANG=en_GB.utf8, LC_CTYPE=en_GB.utf8 (charmap=UTF-8)
Shell: /bin/sh linked to /bin/bash

Versions of packages minicom depends on:
ii  libc6 2.11.3-2   Embedded GNU C Library: Shared lib
ii  libncurses5   5.7+20100313-5 shared libraries for terminal hand

Versions of packages minicom recommends:
ii  lrzsz 0.12.21-5  Tools for zmodem/xmodem/ymodem fil

minicom suggests no packages.

-- no debconf information



-- 
To UNSUBSCRIBE, email to debian-bugs-dist-requ...@lists.debian.org
with a subject of unsubscribe. Trouble? Contact listmas...@lists.debian.org