Bug#473634: obexftp: does not work with Siemens S55 via serial cable

2008-03-31 Thread Jakub Wilk

Package: obexftp
Version: 0.19-7
Severity: normal

Siemens S55 is listed[1] as a supported device, but obexftp fails to 
establish a connection.


[1] http://dev.zuckschwerdt.org/openobex/wiki/SupportedPhonesSiemens 



$ scmxx -d /dev/ttyS0 -i | head -n 4
Using UTF-8 as system character set.
Accessing device /dev/ttyS0...done
OK, a modem device is present.
Phone related information:
Vendor:   SIEMENS
Model:S55
Revision: 16

$ obexftp -t /dev/ttyS0 -Y

=== Probing with FBS uuid.
Connecting...failed: connect
Still trying to connect
Connecting...failed: connect
Still trying to connect
Connecting...failed: connect
Still trying to connect
couldn't connect.

=== Probing with S45 uuid.
Connecting...failed: FBS UUID
Still trying to connect
Connecting...failed: FBS UUID
Still trying to connect
Connecting...failed: FBS UUID
Still trying to connect
couldn't connect.

=== Probing without uuid.
Connecting...failed: FBS UUID
Still trying to connect
Connecting...failed: FBS UUID
Still trying to connect
Connecting...failed: FBS UUID
Still trying to connect
couldn't connect.

End of probe.



-- System Information:
Debian Release: lenny/sid
  APT prefers testing
  APT policy: (900, 'testing'), (600, 'unstable'), (500, 'experimental')
Architecture: i386 (i686)

Kernel: Linux 2.6.24-1-686 (SMP w/2 CPU cores)
Locale: LANG=C, LC_CTYPE=pl_PL.utf8 (charmap=UTF-8)
Shell: /bin/sh linked to /bin/dash

Versions of packages obexftp depends on:
ii  libbluetooth2  3.26-1Library to use the BlueZ Linux Blu
ii  libc6  2.7-6 GNU C Library: Shared libraries
ii  libopenobex1   1.3+cvs20070425-2 OBEX protocol library

obexftp recommends no packages.

-- no debconf information

--
Jakub Wilk



--
To UNSUBSCRIBE, email to [EMAIL PROTECTED]
with a subject of unsubscribe. Trouble? Contact [EMAIL PROTECTED]



Bug#473634: obexftp: does not work with Siemens S55 via serial cable

2008-03-31 Thread Hendrik Sattler
Am Montag 31 März 2008 schrieb Jakub Wilk:
 Package: obexftp
 Version: 0.19-7
 Severity: normal

 Siemens S55 is listed[1] as a supported device, but obexftp fails to
 establish a connection.

Works for mine (and I wrote the patch for obexftp that actually makes it 
work). scmxx gives me:
Hersteller:SIEMENS
Modell:S55
Revision:  91
[...]

 $ obexftp -t /dev/ttyS0 -Y

 === Probing with FBS uuid.
 Connecting...failed: connect
 Still trying to connect
 Connecting...failed: connect
 Still trying to connect
 Connecting...failed: connect
 Still trying to connect
 couldn't connect.

 === Probing with S45 uuid.
 Connecting...failed: FBS UUID
 Still trying to connect
 Connecting...failed: FBS UUID
 Still trying to connect
 Connecting...failed: FBS UUID
 Still trying to connect
 couldn't connect.

For using the S55 over serial cable, you MUST connect using UUID S45. Trying 
any other other UUID breaks the firmware and you must power-cycle the phone.
OTOH, using the S55 over Bluetooth, you must use UUID FBS.
Never use -Y though, not sure what it if for, anyway.
The following shows on my S55:
$ obexftp -t /dev/ttyS0  -U S45 -l
Using S45 uuid.
Connecting...done
Receiving (null)...|?xml version=1.0?
!DOCTYPE folder-listing SYSTEM obex-folder-listing.dtd
folder-listing version=1.0
[...]
/folder-listing
done
Disconnecting...done

Anyway, using bluetooth is way more stable, more versatile and the dongle is 
cheaper than the cable...

HS