AW: CSEUG - September, Germany

2024-03-04 Thread S . Brüseke - proIO GmbH
Hi Ivet, I would love to do a talk at this event. This time a technical one instead of a user story if this makes sense. Regards, Swen -Ursprüngliche Nachricht- Von: Ivet Petrova Gesendet: Mittwoch, 28. Februar 2024 16:29 An: dev ; us...@cloudstack.apache.org Cc: Apache CloudStack

AW: AW: user-data/meta-data

2016-03-14 Thread S . Brüseke - proIO GmbH
, but it should use the name of the network in CS, right? Mit freundlichen Grüßen / With kind regards, Swen -Ursprüngliche Nachricht- Von: Remi Bergsma [mailto:rberg...@schubergphilis.com] Gesendet: Montag, 14. März 2016 11:34 An: S. Brüseke - proIO GmbH; dev@cloudstack.apache.org Betref

AW: user-data/meta-data

2016-03-14 Thread S . Brüseke - proIO GmbH
n Grüßen / With kind regards, Swen -Ursprüngliche Nachricht- Von: Remi Bergsma [mailto:rberg...@schubergphilis.com] Gesendet: Samstag, 12. März 2016 02:18 An: dev@cloudstack.apache.org; S. Brüseke - proIO GmbH Betreff: Re: user-data/meta-data Hi Swen, So you need an extra parameter wi

user-data/meta-data

2016-03-11 Thread S . Brüseke - proIO GmbH
Hi to all, I am testing cloud-init right now and run into a limitation of CS with the provided user-data/meta-data. As far as docu goes (http://docs.cloudstack.apache.org/projects/cloudstack-administration/en/latest/virtual_machines.html#user-data-and-meta-data) CS is providing the following

Problem with storage live migration

2015-12-21 Thread S . Brüseke - proIO GmbH
Hi, we ran into a problem with storage live migration in CLoudstack and need your help to verify this. We are using XenServer with local storage. Steps to reproduce: 1. create an instance from an ISO (not template!) on local storage 2. while instance is running migrate it to another XenServer

AW: [DISCUSS] XenServer and HA: the way forward

2015-05-05 Thread S . Brüseke - proIO GmbH
Please correct me if I am wrong, but does that mean that in CS 4.3 a crash of the pool master will disable the cluster for CS?!? As a technician I feel more save to add a new host to a cluster using XenCenter because of shared storage, NICs and other stuff. CS then needs to discover the new

AW: [DISCUSS] XenServer and HA: the way forward

2015-05-05 Thread S . Brüseke - proIO GmbH
In my opinion the way we should go is keep it simple. We really should consider to drop support for XenServer 6.0.2 here and not making things more complicated and provide more than 1 option. Of course it depends on how many CS installations are still using XenServer 6.0.2.! Can somebody give

AW: Next ACS release?

2015-04-22 Thread S . Brüseke - proIO GmbH
In my opinion we need to improve QA! If smaller cycles will help to do that this is the way to go. I joined this list after the release of 4.5, but as far as I know 4.5 is not really usable for production because of critical bugs in it that good QA would not have passed. So if CS releases new

AW: [DISCUSS] 4.6 release management

2015-04-20 Thread S . Brüseke - proIO GmbH
Hi all, it is really hard for a newbie to follow all of your thought regarding this. Can somebody please explain it a little bit more? Thank you very much! Mit freundlichen Grüßen / With kind regards, Swen Brüseke -Ursprüngliche Nachricht- Von: Simon Weller [mailto:swel...@ena.com]

AW: Missing storage label in XenCenter after migrate

2015-04-15 Thread S . Brüseke - proIO GmbH
Hi, thank you for testing. In 4.3 the name label is empty even when the vm is down. Mit freundlichen Grüßen / With kind regards, Swen Brüseke Von: raja sekhar [mailto:rajsekhar@gmail.com] Gesendet: Dienstag, 14. April 2015 18:48 An: dev@cloudstack.apache.org; S. Brüseke - proIO GmbH

searching for a cloudstack developer

2015-04-15 Thread S . Brüseke - proIO GmbH
Hi, we are searching for a cloudstack developer! We found and reported some bugs in CS, which are really annoying for our workflow, but minor to the opensource project. The problem is that we do not have the knowlegde and manpower to solve these bugs, but we are willing to pay for a solution

AW: Missing storage label in XenCenter after migrate

2015-04-15 Thread S . Brüseke - proIO GmbH
Cannot confirm this! Are you talking about XenServer name-label or CS? Mit freundlichen Grüßen / With kind regards, Swen Brüseke Von: raja sekhar [mailto:rajsekhar@gmail.com] Gesendet: Mittwoch, 15. April 2015 09:43 An: S. Brüseke - proIO GmbH Cc: dev@cloudstack.apache.org Betreff: Re

AW: List of freelance developers (Was: Re: searching for a cloudstack developer)

2015-04-15 Thread S . Brüseke - proIO GmbH
developers (Was: Re: searching for a cloudstack developer) On Apr 15, 2015, at 10:20 AM, Erik Weber terbol...@gmail.com wrote: On Wed, Apr 15, 2015 at 10:05 AM, S. Brüseke - proIO GmbH s.brues...@proio.com wrote: Hi, we are searching for a cloudstack developer! We found and reported

Missing storage label in XenCenter after migrate

2015-04-14 Thread S . Brüseke - proIO GmbH
Hi, can somebody please test this behavior in 4.5.1-rc2? 1. Create instance on XenServer hypervisor via CS. 2. Check Name of storage in XenCenter's storage tab for this instance. (should be ROOT-XXX) 3. Migrate primary storage to different storage via CS. 4. Take a look at Name of storage in

extract a snapshot

2015-04-07 Thread S . Brüseke - proIO GmbH
Hello, is somebody already working on a solution to extract a snapshot of a volume directly without the need to create a new volume before extracting? As far as I understand CS is creating a symlink on the secondary storage in /var/www/html/userdata which points to the corresponding vhd file on

AW: extract a snapshot

2015-04-07 Thread S . Brüseke - proIO GmbH
GmbH Betreff: Re: extract a snapshot I dont think so. Can you log an enhancement request in jira? ~Rajani On Tue, Apr 7, 2015 at 5:56 PM, S. Brüseke - proIO GmbH s.brues...@proio.com wrote: Hello, is somebody already working on a solution to extract a snapshot of a volume directly