https://issues.apache.org/jira/browse/DELTASPIKE-1198?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Mark Struberg resolved DELTASPIKE-1198.
---------------------------------------
       Resolution: Fixed
    Fix Version/s: 1.9.0

> BeanManagerProvider.isActive() returns true after container shutdown
> --------------------------------------------------------------------
>
>                 Key: DELTASPIKE-1198
>                 URL: https://issues.apache.org/jira/browse/DELTASPIKE-1198
>             Project: DeltaSpike
>          Issue Type: Bug
>          Components: Core
>    Affects Versions: 1.7.0, 1.7.2
>            Reporter: Sean Flanigan
>            Assignee: Mark Struberg
>            Priority: Major
>             Fix For: 1.9.0
>
>
> While trying to implement DELTASPIKE-1197 I found that 
> {{BeanManagerProvider.isActive()}} returns true after container shutdown.
> The javadocs for {{isActive()}} say "@return true if the BeanManagerProvider 
> is ready to be used", but when it is in this state, the BeanManagerProvider 
> can't actually be used because the CDI container is not active. 
> In the case of Weld, when {{BeanProvider.getContextualReference()}} was 
> called I got errors like "java.lang.IllegalStateException: Singleton not set 
> for STATIC_INSTANCE => []". There was no stack trace, but that message comes 
> from Weld's RegistrySingletonProvider.java.
> It would seem reasonable to reset bmpSingleton to null during 
> cleanupStoredBeanManagerOnShutdown, but for some reason this breaks a lot of 
> tests.



--
This message was sent by Atlassian JIRA
(v7.6.3#76005)

Reply via email to