Dawid Wysakowicz created FLINK-29500:
----------------------------------------

             Summary: InitializeOnMaster uses wrong parallelism with 
AdaptiveScheduler
                 Key: FLINK-29500
                 URL: https://issues.apache.org/jira/browse/FLINK-29500
             Project: Flink
          Issue Type: Bug
          Components: API / Core, Runtime / Coordination
    Affects Versions: 1.14.6, 1.15.2, 1.16.0
            Reporter: Dawid Wysakowicz


{{InputOutputFormatVertex}} uses {{JobVertex#getParallelism}} to invoke 
{{InitializeOnMaster#initializeGlobal}}. However, this parallelism might not be 
the actual one which will be used to execute the node in combination with 
Adaptive Scheduler. In case of Adaptive Scheduler the execution parallelism is 
provided via {{VertexParallelismStore}}.



--
This message was sent by Atlassian Jira
(v8.20.10#820010)

Reply via email to