Rui Fan created FLINK-30250:
-------------------------------

             Summary: The flame graph type is wrong
                 Key: FLINK-30250
                 URL: https://issues.apache.org/jira/browse/FLINK-30250
             Project: Flink
          Issue Type: Bug
          Components: Runtime / REST, Runtime / Web Frontend
    Affects Versions: 1.16.0, 1.15.0, 1.17.0
            Reporter: Rui Fan
             Fix For: 1.17.0
         Attachments: image-2022-11-30-19-08-42-067.png

When the flame graph type is switched from On-CPU to Mixed. It still show the 
graph of On-CPU.
h2. Root cause:

When click the other types, the web frontend will call the requestFlameGraph 
and update the graphType. However, the graphType is the old type during 
requestFlameGraph. So the graph type show the new type, but the flame graph is 
the result of old type.

 [code link 
|https://github.com/apache/flink/blob/8bbf52688758bbede45df060a4c11e5fa228b6f0/flink-runtime-web/web-dashboard/src/app/pages/job/overview/flamegraph/job-overview-drawer-flamegraph.component.ts#L82]

!image-2022-11-30-19-08-42-067.png|width=1026,height=389!



--