Elias Levy created FLINK-8751:
---------------------------------

             Summary: Canceling a job results in a InterruptedException in the 
JM
                 Key: FLINK-8751
                 URL: https://issues.apache.org/jira/browse/FLINK-8751
             Project: Flink
          Issue Type: Bug
          Components: JobManager
    Affects Versions: 1.4.1
            Reporter: Elias Levy


Canceling a job results in the following exception reported by the JM: 
{code:java}
ERROR org.apache.flink.streaming.runtime.tasks.StreamTask           - Could not 
shut down timer service java.lang.InterruptedException 
  at 
java.util.concurrent.locks.AbstractQueuedSynchronizer$ConditionObject.awaitNanos(Unknown
 Source) at java.util.concurrent.ThreadPoolExecutor.awaitTermination(Unknown 
Source) 
  at 
org.apache.flink.streaming.runtime.tasks.SystemProcessingTimeService.shutdownAndAwaitPending(SystemProcessingTimeService.java:197)
 
  at 
org.apache.flink.streaming.runtime.tasks.StreamTask.invoke(StreamTask.java:317) 
at org.apache.flink.runtime.taskmanager.Task.run(Task.java:718) 
  at java.lang.Thread.run(Unknown Source){code}
 



--
This message was sent by Atlassian JIRA
(v7.6.3#76005)

Reply via email to