Hi Jukka,
and I should mention, that EIP support is probably the least tested driver
regarding features.
This is due to a lack of hardware for testing. This might change in the (near)
future, but right now
all I had, when developing the driver, was a simple 2 channel digital IO
component.
Hi,
I wanted to debug something in plc4j/modbus and simply opened the project
in IntelliJ as a maven project.
I build the whole thing and then try to run one of the tests in the
debugger.
The problem I have is that before it starts the debugger IntelliJ does a
build step and that starts using
I have just
1) Done a full local install into my local maven repo (~/.m2)
2) Commented out the entire code-generation module
3) Now it all works very well.
Niels
On Fri, Jan 6, 2023 at 2:30 PM Niels Basjes wrote:
> Hi,
>
> I wanted to debug something in plc4j/modbus and simply opened the
Hi Niels,
even if I’m happy it seems to be working for you, it’s still odd that you were
having such issues.
Usually, you don’t need to comment out the code generation as in 90% of the
times it doesn’t really change anything.
When you do the build, it just generates new versions, which are
sruehl merged PR #730:
URL: https://github.com/apache/plc4x/pull/730
--
This is an automated message from the Apache Git Service.
To respond to the message, please log on to GitHub and use the
URL above to go to the specific comment.
To unsubscribe, e-mail: dev-unsubscr...@plc4x.apache.org
Hi Niels,
I had noticed this yesterday while working on another branch, after merging
develop into it, I hadn't been able to track down exactly what was causing
the problem.
Ben
On Fri, Jan 6, 2023 at 3:27 PM Christofer Dutz
wrote:
> Hi Niels,
>
> even if I’m happy it seems to be working for
What version of IntelliJ are you using? I think I recently upgraded to
2022.2.4.
On Fri, 6 Jan 2023 at 5:57 pm, Ben Hutcheson wrote:
> Hi Niels,
>
> I had noticed this yesterday while working on another branch, after
> merging develop into it, I hadn't been able to track down exactly what was
>
Hi Niels,
I tried upgrading to 2022.3.1, which didn't seem to work. However when I
changed the compiler within Settings->Build, Execution,
Deployment->Compiler->Java Compiler->Use Compiler from Eclipse to Javac it
seems to have started working.
I also tried changing the SDK in project settings
hongjinlin commented on PR #545:
URL: https://github.com/apache/plc4x/pull/545#issuecomment-1374359457
@chrisdutz
Hi Chris,
I have updated it, and have a
commit([17d7f7](https://github.com/apache/plc4x/commit/17d7f765c670f86c3fd110f010a3faafe8ee1c5a))
about it, please review it
Hi,
There's been a few times where I have had to pass the connection string
information through to the driver logic to be used in the connection phase.
For OPC-UA it's passed as a string through to the OPCUA device to help
select the correct endpoint. As well as now in the Profinet driver as we
Hi Chris,
It’s so appreciated for your invitation. Of course, I like to attend the
event, but it is unrealistic for me, because of many limitations such as
money, free time, and the abroad experience, I haven't even ever left China
before.
I like to dream I can see all of you one day, if I have a
11 matches
Mail list logo