The Zynq CPU cannot possibly sustain sample rates of 10s of MSPS. The E3xx
series have larger FPGAs that support the RFNOc framework that support high
sample rate signal flows within the FPGA.
Sent from my iPhone
> On Apr 12, 2021, at 10:55 PM, Louis Jung wrote:
>
> Hi all,
>
> I’m
It looks like the sink label/name is not rendered for the QT Sink.
On 12/04/2021 13:30, alberto.alle...@alice.it wrote:
Hi to all!
Today i have another question..
I have created a small spectrum analyzer and it work fine.
But, in the QT GUI SINK, at "Name" field i have writted
I would have implement this differently:
First solution combine To filters taps in one filter such as
final_taps=rrc_taps*(pulse-1)+rect*pulse
with pulse =0 or 1 (obtainde with a QT GUI Chooser)
BUT filters must have the same
Hi Cinaed,
nope, that sets the id, i.e. the name of the Python object. That can't affect
the Text
displayed.
Best regards,
Marcus
On 12.04.21 21:33, Cinaed Simson wrote:
>
> Hi Alberto - in the GRC file, open the
>
> Options
>
> block and set the
>
> Id
>
> field to
>
> test
>
>
Hi Alberto,
you're mixing things up:
the window title is not the title of the Qt GUI Sink. You can have many of
these in one
window!
You set the window title in the "Options" block.
Best regards,
Marcus
On 12.04.21 13:30, alberto.alle...@alice.it wrote:
> Hi to all!
> Today i have another
Hi Alberto - in the GRC file, open the
Options
block and set the
Id
field to
test
Doesn't need quotes - and in general no hyphens - use underscore instead.
-- Cinaed
On 4/12/21 4:30 AM, alberto.alle...@alice.it wrote:
Hi to all!
Today i have another question..
I have created
This is true. Take a look at the generated isi.py. The pulse options are
generated statically and changes are not propagated through the chooser.
Not a bug, really, but propagation of variables is not consistent
everywhere.
On Mon, Apr 12, 2021 at 1:14 PM Achilleas Anastasopoulos
wrote:
> Hi
Hi all,
I have a flowgraph with QT chooser choosing between rect pulse and rrc
pulse.
I also have a QT range where I want to control the rolloff factor of the
rrc pulse when chosen.
However, in the flowgrpah it seems that once the rrc is chosen I cannot
change its roloff factor dynamically from
You entered Test, but I think you needed to enter “Test” (with quotes) as I
think this is a string.
Kind Regards,
Nik
(Sent from a mobile device)
> On 12 Apr 2021, at 12:47, alberto.alle...@alice.it wrote:
>
>
> Hi to all!
> Today i have another question..
>
> I have created a small