, 2014 2:04 PM
To: Lapointe, Benjamin - 1008 - MITLL
Cc: discuss-gnuradio@gnu.org
Subject: Re: [Discuss-gnuradio] sample time alignment in GRC
Make sure that you specify that the 2nd X310 uses external clock and 1PPS, and
all of them should use time synch of
unknown PPS.
Also, there has
:04 PM
*To:* Lapointe, Benjamin - 1008 - MITLL
*Cc:* discuss-gnuradio@gnu.org
*Subject:* Re: [Discuss-gnuradio] sample time alignment in GRC
Make sure that you specify that the 2nd X310 uses external clock and
1PPS, and all of them should use time synch of
unknown PPS.
Also, there has been
@gnu.org
Subject: Re: [Discuss-gnuradio] sample time alignment in GRC
On 06/17/2014 09:58 AM, Lapointe, Benjamin - 1008 - MITLL wrote:
Hi All,
I am still having trouble time aligning sample streams from two USRP X310
devices. In GRC I noticed a random time offset from run to run
Hi,
I have two USRP X310 devices that I am trying to time align in GNU Radio
Companion. One X310 has a GPSDO that is sending 10 MHz reference and 1 PPS
signals to the other one. The GPS is locked. Ideally I would have matched
length cables for 10 MHz reference and 1 PPS, but I think my setup
Make sure that you specify that the 2nd X310 uses external clock and 1PPS, and all of them should use time synch of
"unknown PPS".
Also, there has been a bug in the scope sink (dunno if fixed) where samples are *not* time-aligned in the scope sink. The except
is that a complex-pair will be