Best regards,
> Zoltán
>
>
> -Original Message-
> From: Ben Pfaff [mailto:b...@ovn.org]
> Sent: Thursday, September 15, 2016 8:44 PM
> To: Zoltán Balogh
> Cc: discuss@openvswitch.org
> Subject: Re: [ovs-discuss] mirror ports on multiple bridges - egress proble
when the bug was detected.
Reported-by: Sugesh Chandran
Best regards,
Zoltán
-Original Message-
From: Ben Pfaff [mailto:b...@ovn.org]
Sent: Thursday, September 15, 2016 8:44 PM
To: Zoltán Balogh
Cc: discuss@openvswitch.org
Subject: Re: [ovs-discuss] mirror ports on multiple bridges
On Thu, Sep 15, 2016 at 11:05:58AM -0700, Ben Pfaff wrote:
> On Thu, Sep 15, 2016 at 07:52:03AM +, Zoltán Balogh wrote:
> > It seems that for each datapath flow rule, there can be only one mirror
> > port.
> > I presume the chosen port could depend on the processing order of output
> > ports
On Thu, Sep 15, 2016 at 07:52:03AM +, Zoltán Balogh wrote:
> It seems that for each datapath flow rule, there can be only one mirror port.
> I presume the chosen port could depend on the processing order of output
> ports
> when the datapath flow is constructed.
> Is this a planned limitatio