Looking for a Fox Tango YF-56H2.IF 2.1 SSB Filter , FL-2400, or similar for
Drake R-4C
Tnx
Martin, OZCXX
m...@forum.dk
___
Drakelist mailing list
Drakelist@zerobeat.net
http://mailman.zerobeat.net/mailman/listinfo/drakelist
My TR-4C's s-meter points to S-9 under no signal condition. Adjusting the
sensitivity and the zero pot won't correct it. I also noticed its reduced
sensitivity compared to other Drakes that I have. The s-meter moves as expected
when RF gain is lowered. Checked/replaced all tubes. I also checked
Kihwal -
Check Pin 2 of V17 for resistance to ground (270 Ohms) and voltage ~7.5 VDC.
73, Garey - K4OAH
Glen Allen, VA
Drake 2-B, 2-C/2-NT, 4-A, 4-B, C-Line
and TR-4/C Service Supplement CDs
www.k4oah.com
Kihwal Lee wrote:
My TR-4C's s-meter points to S-9 under no signal condition.
It's 290 ohm and the following are the voltage levels.
pin1 0.2v
pin2 12v
pin5 237v
pin6 246v
Probably I should check the R's around the meter as the pin6 voltage seems a
bit high. Any other suggestion?
Thanks
Kihwal K9SUL
On Apr 14, 2011, at 2:29 PM, Garey Barrell k4...@mindspring.com
Kihwal -
OK. Most likely problem is a leaky C212. That Cathode (pin 1) voltage
is way too high. the stage is drawing ~42 mA rather than the 28 mA it
should be. Check R185, and disconnect C212. The Cathode voltage should
drop to around 7.5 VDC. R92 is about 7% high, so in tolerance, but
What size screws are used in the case for a L4B PS? Just got a nice
amp...but the screws were missing on the case for the Power Supply?
Thanks...
Rich N7TR
ex KI3V, N3AMK, WB3JOV
www.n7tr.com http://www.n7tr.com
Telnet: dxc.n7tr.com N7TR DXCluster
6 matches