Help!
- Original Message -
With no incoming signals, including crystal calibrator, and with C-130 adjusted
for equal sounding white noise when switching between
Lower and Upper I am unable to zero the S-meter in both sidebands. It will
zero with one or the other and then the
-4C S meter meter zero
Help!
- Original Message -
With no incoming signals, including crystal calibrator, and with C-130 adjusted
for equal sounding white noise when switching between
Lower and Upper I am unable to zero the S-meter in both sidebands. It will
zero with one
It’s a common problem with all of the TR-4 models, usually the LSB filter ( LSB
on 80 meters ).
73, Gary
http://home.roadrunner.com/~w8pu
R-4A T4-X R-4B T4-XB R-4C T4-XC MS-4 L-4B RCS-4
2A 2B 2C 2NT 2CQ 2AS 4-LF
TR-4 TR-4C TR-4CW/RIT RV-4C MC-4
TR-7 RV-7 CW-75 MS-7
WH-7 W-4 WV-4 MN-2700
3 matches
Mail list logo