Earlier I posted that R36 to ground was only 108 Ohms ...
--
I've already received an off Reflector reply from Elecraft Support, that
this specific low reading is typical of some DMMs. Total turn around time,
2 hours and 12 minutes! :>)
_
One of the four resistance measurements (prior to the initial power on / smoke
test) is low by about 30% ...
1. The resistance across the power pole connectors is ~1.1 Meg Ohms (looking
for > 50 k Ohms). (GOOD!)
2. R36 to ground was only 108 Ohms (looking for > 150 Ohms). I tried reversing
t